Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr PowerGrids_dev_PowerGrids.Examples.IEEE14bus.IEEE14busShort4.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/package.mo", uses=false) Using package PowerGrids with version 2.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(PowerGrids.Examples.IEEE14bus.IEEE14busShort4,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="PowerGrids_dev_PowerGrids.Examples.IEEE14bus.IEEE14busShort4") translateModel(PowerGrids.Examples.IEEE14bus.IEEE14busShort4,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="PowerGrids_dev_PowerGrids.Examples.IEEE14bus.IEEE14busShort4") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.00129/0.00129, allocations: 112.7 kB / 16.42 MB, free: 5.977 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001125/0.001125, allocations: 189.2 kB / 17.36 MB, free: 5.594 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.149/1.149, allocations: 222.9 MB / 241.1 MB, free: 15.14 MB / 206.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/package.mo): time 0.06731/0.06731, allocations: 16.79 MB / 308 MB, free: 14.41 MB / 254.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 1.144e-05/1.144e-05, allocations: 4.672 kB / 427.3 MB, free: 10.54 MB / 302.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus1.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus1.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus2.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus2.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus3.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus3.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus4.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus4.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus5.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus5.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus6.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus6.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus7.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus7.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus8.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus8.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus9.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus9.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus10.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus10.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus11.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus11.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus12.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus12.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus13.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus13.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus14.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus14.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter busGEN1.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter busGEN1.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter busGEN2.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter busGEN2.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter busGEN3.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter busGEN3.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter busGEN8.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter busGEN8.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L1to2.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L1to2.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L1to5.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L1to5.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L2to3.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L2to3.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L2to4.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L2to4.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L2to5.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L2to5.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L3to4.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L3to4.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L4to5.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L4to5.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L6to11.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L6to11.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L6to12.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L6to12.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L6to13.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L6to13.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L7to8.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L7to8.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L7to9.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L7to9.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L9to10.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L9to10.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L9to14.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L9to14.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L10to11.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L10to11.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L12to13.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L12to13.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L13to14.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L13to14.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load2.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load2.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load3.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load3.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load4.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load4.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load5.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load5.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load6.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load6.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load9.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load9.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load10.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load10.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load11.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load11.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load12.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load12.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load13.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load13.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load14.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load14.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Cbank9.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Cbank9.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter T4to7.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter T4to7.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter T4to9.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter T4to9.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter T5to6.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter T5to6.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter Tgen1.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter Tgen1.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter Tgen2.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter Tgen2.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter Tgen3.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter Tgen3.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter Tgen8.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter Tgen8.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter GEN1.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter GEN1.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter GEN1.GEN.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter GEN1.GEN.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter GEN2.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter GEN2.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter GEN2.GEN.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter GEN2.GEN.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter GEN3.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter GEN3.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter GEN3.GEN.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter GEN3.GEN.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter GEN6.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter GEN6.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter GEN6.GEN.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter GEN6.GEN.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter GEN8.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter GEN8.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter GEN8.GEN.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter GEN8.GEN.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter FAULT4.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter FAULT4.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. Notification: Performance of NFInst.instantiate(PowerGrids.Examples.IEEE14bus.IEEE14busShort4): time 0.9752/0.9752, allocations: 0.5155 GB / 0.9327 GB, free: 19.71 MB / 0.5762 GB Notification: Performance of NFInst.instExpressions: time 0.1286/1.104, allocations: 103 MB / 1.033 GB, free: 11.66 MB / 0.5919 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.04568/1.15, allocations: 0.911 MB / 1.034 GB, free: 11.4 MB / 0.5919 GB Notification: Performance of NFTyping.typeComponents: time 0.0218/1.171, allocations: 7.867 MB / 1.042 GB, free: 5.555 MB / 0.5919 GB Notification: Performance of NFTyping.typeBindings: time 0.05558/1.227, allocations: 21.91 MB / 1.063 GB, free: 6.145 MB / 0.6075 GB Notification: Performance of NFTyping.typeClassSections: time 0.02445/1.252, allocations: 9.999 MB / 1.073 GB, free: 76 kB / 0.6075 GB Notification: Performance of NFFlatten.flatten: time 0.06736/1.319, allocations: 59.05 MB / 1.131 GB, free: 6.281 MB / 0.67 GB Notification: Performance of NFFlatten.resolveConnections: time 0.01797/1.337, allocations: 8.684 MB / 1.139 GB, free: 13.68 MB / 0.6856 GB Notification: Performance of NFEvalConstants.evaluate: time 0.02854/1.365, allocations: 17.94 MB / 1.157 GB, free: 12.04 MB / 0.7012 GB Notification: Performance of NFSimplifyModel.simplify: time 0.6093/1.975, allocations: 21.19 MB / 1.177 GB, free: 32.72 MB / 0.7013 GB Notification: Performance of NFPackage.collectConstants: time 0.008078/1.983, allocations: 1.673 MB / 1.179 GB, free: 32.72 MB / 0.7013 GB Notification: Performance of NFFlatten.collectFunctions: time 0.02097/2.004, allocations: 4.211 MB / 1.183 GB, free: 32.72 MB / 0.7013 GB Notification: Performance of combineBinaries: time 0.0566/2.061, allocations: 58.14 MB / 1.24 GB, free: 10.17 MB / 0.7013 GB Notification: Performance of replaceArrayConstructors: time 0.02875/2.089, allocations: 35.63 MB / 1.275 GB, free: 4.461 MB / 0.7169 GB Notification: Performance of NFVerifyModel.verify: time 0.01309/2.102, allocations: 4.608 MB / 1.279 GB, free: 3.641 MB / 0.7169 GB Notification: Performance of FrontEnd: time 0.003924/2.106, allocations: 0.7517 MB / 1.28 GB, free: 3.566 MB / 0.7169 GB