Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr IDEAS_dev_IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/package.mo", uses=false) Using package IDEAS with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IDEAS_dev_IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years") translateModel(IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IDEAS_dev_IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.00114/0.00114, allocations: 106.8 kB / 16.42 MB, free: 6.035 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001221/0.001222, allocations: 190.6 kB / 17.35 MB, free: 5.598 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.496/1.496, allocations: 222.9 MB / 241 MB, free: 15.18 MB / 206.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/package.mo): time 0.8596/0.8596, allocations: 135.1 MB / 426.3 MB, free: 4.102 MB / 334.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 2.421e-05/2.422e-05, allocations: 2.5 kB / 0.5862 GB, free: 21.65 MB / 446.1 MB Notification: Performance of NFInst.instantiate(IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years): time 0.004003/0.004036, allocations: 2.679 MB / 0.5889 GB, free: 19.57 MB / 446.1 MB Notification: Performance of NFInst.instExpressions: time 0.007637/0.01169, allocations: 5.979 MB / 0.5947 GB, free: 14.03 MB / 446.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.0003788/0.0121, allocations: 9 kB / 0.5947 GB, free: 14.02 MB / 446.1 MB Notification: Performance of NFTyping.typeComponents: time 0.001731/0.01384, allocations: 0.5431 MB / 0.5952 GB, free: 13.5 MB / 446.1 MB Notification: Performance of NFTyping.typeBindings: time 0.000995/0.0149, allocations: 244.5 kB / 0.5955 GB, free: 13.27 MB / 446.1 MB Notification: Performance of NFTyping.typeClassSections: time 0.004385/0.0193, allocations: 1.471 MB / 0.5969 GB, free: 11.8 MB / 446.1 MB Notification: Performance of NFFlatten.flatten: time 0.0006601/0.01997, allocations: 0.5181 MB / 0.5974 GB, free: 11.29 MB / 446.1 MB Notification: Performance of NFFlatten.resolveConnections: time 0.0001568/0.02013, allocations: 51.09 kB / 0.5975 GB, free: 11.24 MB / 446.1 MB Notification: Performance of NFEvalConstants.evaluate: time 0.0002546/0.02039, allocations: 207.6 kB / 0.5977 GB, free: 11.04 MB / 446.1 MB Notification: Performance of NFSimplifyModel.simplify: time 0.0008415/0.02124, allocations: 0.6772 MB / 0.5983 GB, free: 10.38 MB / 446.1 MB Notification: Performance of NFPackage.collectConstants: time 6.962e-05/0.02132, allocations: 36 kB / 0.5984 GB, free: 10.34 MB / 446.1 MB Notification: Performance of NFFlatten.collectFunctions: time 0.00323/0.02456, allocations: 2.149 MB / 0.6005 GB, free: 8.191 MB / 446.1 MB Notification: Performance of combineBinaries: time 0.0004208/0.025, allocations: 0.7362 MB / 0.6012 GB, free: 7.449 MB / 446.1 MB Notification: Performance of replaceArrayConstructors: time 0.0001819/0.02519, allocations: 457.4 kB / 0.6016 GB, free: 6.996 MB / 446.1 MB Notification: Performance of NFVerifyModel.verify: time 6.371e-05/0.02526, allocations: 51.81 kB / 0.6017 GB, free: 6.945 MB / 446.1 MB Notification: Performance of FrontEnd: time 6.418e-05/0.02533, allocations: 7.938 kB / 0.6017 GB, free: 6.938 MB / 446.1 MB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFBackendExtension.mo:1178:11-1178:133:writable] Error: Internal error NFBackendExtension.VariableAttributes.createRecord got unknown record child: mBor_flow_small Error: Internal error NBackendDAE.lowerVariable failed for parameter IDEAS.Fluid.Geothermal.Borefields.Data.Borefield.Template groTemRes.borFieDat = borFieDat