Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_dev_Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI10.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001376/0.001376, allocations: 81.7 kB / 20.58 MB, free: 1.207 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001536/0.001536, allocations: 167.7 kB / 23.83 MB, free: 4.395 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.151/1.151, allocations: 158.6 MB / 185.6 MB, free: 6.504 MB / 174.1 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/package.mo): time 0.5554/0.5554, allocations: 88.33 MB / 326.2 MB, free: 4.297 MB / 302.1 MB " [Timeout remaining time 179] Using package Dynawo with version 1.8.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI10,tolerance=1e-06,outputFormat="mat",numberOfIntervals=100000,variableFilter="time|Unit.measurements.PPu|loadAlphaBeta.PPu|Unit.measurements.QPu|loadAlphaBeta.QPu|inertialGrid1.omegaPu",fileNamePrefix="Dynawo_dev_Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI10") translateModel(Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI10,tolerance=1e-06,outputFormat="mat",numberOfIntervals=100000,variableFilter="time|Unit.measurements.PPu|loadAlphaBeta.PPu|Unit.measurements.QPu|loadAlphaBeta.QPu|inertialGrid1.omegaPu",fileNamePrefix="Dynawo_dev_Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI10") [Timeout 660] "Notification: Performance of FrontEnd - Absyn->SCode: time 1.752e-05/1.752e-05, allocations: 2.281 kB / 0.4929 GB, free: 23.91 MB / 446.1 MB Notification: Performance of NFInst.instantiate(Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI10): time 0.01432/0.01434, allocations: 15.34 MB / 0.5079 GB, free: 13.64 MB / 446.1 MB Notification: Performance of NFInst.instExpressions: time 0.01325/0.02759, allocations: 7.737 MB / 0.5154 GB, free: 8.02 MB / 446.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.004464/0.03206, allocations: 117.8 kB / 0.5155 GB, free: 7.969 MB / 446.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.003055/0.03511, allocations: 1.052 MB / 0.5165 GB, free: 7.371 MB / 446.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Utilities/Strings.mo:139:3-175:14:writable] Warning: Pure function 'Modelica.Utilities.Strings.isEmpty' contains a call to impure function 'Modelica.Utilities.Strings.Advanced.skipWhiteSpace'. Notification: Performance of NFTyping.typeBindings: time 0.008062/0.04317, allocations: 1.654 MB / 0.5182 GB, free: 6.254 MB / 446.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation bus.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation bus.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Wind/WECC/WT4CurrentSource_INIT.mo:82:3-82:98:writable] Warning: In relation Modelica.ComplexMath.'abs'(INIT.sInj0Pu) == 0.0, == on Real numbers is only allowed inside functions. Notification: Performance of NFTyping.typeClassSections: time 0.008328/0.0515, allocations: 3.611 MB / 0.5217 GB, free: 3.969 MB / 446.1 MB Notification: Performance of NFFlatten.flatten: time 0.01057/0.06207, allocations: 8.379 MB / 0.5299 GB, free: 14.87 MB / 462.1 MB Notification: Performance of NFFlatten.resolveConnections: time 0.003893/0.06596, allocations: 1.463 MB / 0.5313 GB, free: 13.8 MB / 462.1 MB Notification: Performance of NFEvalConstants.evaluate: time 0.003986/0.06995, allocations: 2.928 MB / 0.5342 GB, free: 11.76 MB / 462.1 MB Notification: Performance of NFSimplifyModel.simplify: time 0.002919/0.07287, allocations: 2.286 MB / 0.5364 GB, free: 9.992 MB / 462.1 MB Notification: Performance of NFPackage.collectConstants: time 0.0008396/0.07371, allocations: 0.6814 MB / 0.5371 GB, free: 9.992 MB / 462.1 MB Notification: Performance of NFFlatten.collectFunctions: time 0.00152/0.07523, allocations: 0.9889 MB / 0.538 GB, free: 9.867 MB / 462.1 MB Notification: Performance of combineBinaries: time 0.009758/0.08499, allocations: 11.14 MB / 0.5489 GB, free: 15.09 MB / 478.1 MB Notification: Performance of replaceArrayConstructors: time 0.00574/0.09072, allocations: 6.89 MB / 0.5556 GB, free: 8.113 MB / 478.1 MB Notification: Performance of NFVerifyModel.verify: time 0.001098/0.09182, allocations: 284 kB / 0.5559 GB, free: 7.836 MB / 478.1 MB Notification: Performance of FrontEnd: time 0.001452/0.09327, allocations: 317.5 kB / 0.5562 GB, free: 7.523 MB / 478.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 2.9390956833958626] Failed to read output from testmodel.py, exit status != 0: 0.11571563594043255 0.129196617 0.032981772 Calling exit ...