Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_Dynawo.Examples.SMIB.Standard.GovSteam1St4bPss2b3.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001421/0.001421, allocations: 92.38 kB / 20.48 MB, free: 1.359 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001549/0.001549, allocations: 226.5 kB / 23.79 MB, free: 4.508 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.301/1.301, allocations: 207.7 MB / 234.6 MB, free: 9.789 MB / 190.1 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/package.mo): time 0.556/0.556, allocations: 103.8 MB / 390.7 MB, free: 21.23 MB / 318.1 MB " [Timeout remaining time 179] Using package Dynawo with version 1.7.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Ignoring simflag -noemit -emit_protected=() since it seems broken on HelloWorld Running command: translateModel(Dynawo.Examples.SMIB.Standard.GovSteam1St4bPss2b3,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="Dynawo_Dynawo.Examples.SMIB.Standard.GovSteam1St4bPss2b3") translateModel(Dynawo.Examples.SMIB.Standard.GovSteam1St4bPss2b3,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="Dynawo_Dynawo.Examples.SMIB.Standard.GovSteam1St4bPss2b3") [Timeout 660] "Notification: Performance of FrontEnd - Absyn->SCode: time 2.317e-05/2.317e-05, allocations: 2.281 kB / 0.552 GB, free: 58.1 MB / 462.1 MB Notification: Performance of NFInst.instantiate(Dynawo.Examples.SMIB.Standard.GovSteam1St4bPss2b3): time 0.008851/0.008874, allocations: 9.344 MB / 0.5612 GB, free: 54.05 MB / 462.1 MB Notification: Performance of NFInst.instExpressions: time 0.009483/0.01836, allocations: 5.261 MB / 0.5663 GB, free: 50.36 MB / 462.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.001641/0.02, allocations: 55.84 kB / 0.5664 GB, free: 50.34 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:24:3-24:104:writable] Warning: Connector omegaRefPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:25:3-25:94:writable] Warning: Connector PmPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:26:3-26:125:writable] Warning: Connector efdPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:29:3-29:96:writable] Warning: Connector omegaPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:42:3-42:108:writable] Warning: Connector UStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:43:3-43:115:writable] Warning: Connector IStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:44:3-44:116:writable] Warning: Connector QStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:45:3-45:126:writable] Warning: Connector QStatorPuQNom is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:46:3-46:123:writable] Warning: Connector IRotorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:47:3-47:95:writable] Warning: Connector thetaInternal is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Basics/SetPoint.mo:17:3-17:75:writable] Warning: Connector setPoint is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Events/NodeFault.mo:24:3-24:107:writable] Warning: Connector nodeFault is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.001502/0.0215, allocations: 0.5511 MB / 0.5669 GB, free: 50.03 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Utilities/Strings.mo:139:3-175:14:writable] Warning: Pure function 'Modelica.Utilities.Strings.isEmpty' contains a call to impure function 'Modelica.Utilities.Strings.Advanced.skipWhiteSpace'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/VoltageRegulators/Standard/BaseClasses/RectifierRegulationCharacteristic.mo:22:3-22:139:writable] Warning: In relation avr.rectifierRegulationCharacteristic.ULow == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/VoltageRegulators/Standard/BaseClasses/RectifierRegulationCharacteristic.mo:23:3-23:131:writable] Warning: In relation avr.rectifierRegulationCharacteristic.UHigh == 1.0, == on Real numbers is only allowed inside functions. Notification: Performance of NFTyping.typeBindings: time 0.002119/0.02362, allocations: 0.7787 MB / 0.5677 GB, free: 49.5 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:133:3-133:117:writable] Warning: In relation generatorSynchronous.SNom <> generatorSynchronous.PNomAlt, <> on Real numbers is only allowed inside functions. Notification: Performance of NFTyping.typeClassSections: time 0.00395/0.02757, allocations: 2.298 MB / 0.5699 GB, free: 48.18 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:51:3-51:114:writable] Error: Parameter generatorSynchronous.MdPPuEfd has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:52:3-52:139:writable] Error: Parameter generatorSynchronous.MdPPuEfdNom has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Steam/GovSteam1.mo:48:3-49:25:writable] Error: Parameter governor.PgvTableName has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Steam/GovSteam1.mo:50:3-51:141:writable] Error: Parameter governor.TablesFile has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Types.mo:49:35-49:96:writable] Error: Parameter load.s0Pu.re has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Types.mo:50:35-50:101:writable] Error: Parameter load.s0Pu.im has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Types.mo:49:35-49:96:writable] Error: Parameter load.i0Pu.re has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Types.mo:50:35-50:101:writable] Error: Parameter load.i0Pu.im has neither value nor start value, and is fixed during initialization (fixed=true). Notification: Performance of NFFlatten.flatten: time 0.006021/0.03359, allocations: 5.389 MB / 0.5752 GB, free: 45.61 MB / 462.1 MB Notification: Performance of NFFlatten.resolveConnections: time 0.001533/0.03512, allocations: 0.7015 MB / 0.5758 GB, free: 45.14 MB / 462.1 MB Notification: Performance of NFEvalConstants.evaluate: time 0.002577/0.0377, allocations: 1.764 MB / 0.5776 GB, free: 44.25 MB / 462.1 MB Notification: Performance of NFSimplifyModel.simplify: time 0.002043/0.03974, allocations: 1.588 MB / 0.5791 GB, free: 43.4 MB / 462.1 MB Notification: Performance of NFPackage.collectConstants: time 0.0005794/0.04032, allocations: 324.2 kB / 0.5794 GB, free: 43.4 MB / 462.1 MB Notification: Performance of NFFlatten.collectFunctions: time 0.001355/0.04168, allocations: 0.5824 MB / 0.58 GB, free: 43.32 MB / 462.1 MB Notification: Performance of combineBinaries: time 0.004311/0.04599, allocations: 5.947 MB / 0.5858 GB, free: 39.15 MB / 462.1 MB Notification: Performance of replaceArrayConstructors: time 0.002525/0.04851, allocations: 3.641 MB / 0.5894 GB, free: 36.56 MB / 462.1 MB Notification: Performance of NFVerifyModel.verify: time 0.0006905/0.0492, allocations: 154.2 kB / 0.5895 GB, free: 36.55 MB / 462.1 MB Notification: Performance of FrontEnd: time 0.0006592/0.04986, allocations: 118.7 kB / 0.5896 GB, free: 36.5 MB / 462.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 2.9880882599391043] Failed to read output from testmodel.py, exit status != 0: 0.26437131501734257 0.073865476 0.021606386 Calling exit ...