Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_Dynawo.Examples.SMIB.Standard.GovSteam1St4bPss2b1.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001421/0.001421, allocations: 92.38 kB / 20.48 MB, free: 1.359 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001645/0.001645, allocations: 222.6 kB / 23.79 MB, free: 4.508 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.332/1.332, allocations: 207.7 MB / 234.6 MB, free: 9.789 MB / 190.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/package.mo): time 0.5679/0.5679, allocations: 103.8 MB / 390.7 MB, free: 21.21 MB / 318.1 MB " [Timeout remaining time 179] Using package Dynawo with version 1.7.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Ignoring simflag -noemit -emit_protected=() since it seems broken on HelloWorld Running command: translateModel(Dynawo.Examples.SMIB.Standard.GovSteam1St4bPss2b1,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="Dynawo_Dynawo.Examples.SMIB.Standard.GovSteam1St4bPss2b1") translateModel(Dynawo.Examples.SMIB.Standard.GovSteam1St4bPss2b1,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="Dynawo_Dynawo.Examples.SMIB.Standard.GovSteam1St4bPss2b1") [Timeout 660] "Notification: Performance of FrontEnd - Absyn->SCode: time 2.163e-05/2.163e-05, allocations: 2.828 kB / 0.552 GB, free: 58.17 MB / 462.1 MB Notification: Performance of NFInst.instantiate(Dynawo.Examples.SMIB.Standard.GovSteam1St4bPss2b1): time 0.007637/0.007658, allocations: 8.147 MB / 0.56 GB, free: 54.89 MB / 462.1 MB Notification: Performance of NFInst.instExpressions: time 0.006359/0.01402, allocations: 4.74 MB / 0.5646 GB, free: 51.57 MB / 462.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.001215/0.01523, allocations: 49.72 kB / 0.5647 GB, free: 51.54 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:24:3-24:104:writable] Warning: Connector omegaRefPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:25:3-25:94:writable] Warning: Connector PmPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:26:3-26:125:writable] Warning: Connector efdPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:29:3-29:96:writable] Warning: Connector omegaPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:42:3-42:108:writable] Warning: Connector UStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:43:3-43:115:writable] Warning: Connector IStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:44:3-44:116:writable] Warning: Connector QStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:45:3-45:126:writable] Warning: Connector QStatorPuQNom is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:46:3-46:123:writable] Warning: Connector IRotorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:47:3-47:95:writable] Warning: Connector thetaInternal is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Basics/SetPoint.mo:17:3-17:75:writable] Warning: Connector setPoint is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.001128/0.01636, allocations: 471.3 kB / 0.5651 GB, free: 51.28 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/VoltageRegulators/Standard/BaseClasses/RectifierRegulationCharacteristic.mo:22:3-22:139:writable] Warning: In relation avr.rectifierRegulationCharacteristic.ULow == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/VoltageRegulators/Standard/BaseClasses/RectifierRegulationCharacteristic.mo:23:3-23:131:writable] Warning: In relation avr.rectifierRegulationCharacteristic.UHigh == 1.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Utilities/Strings.mo:139:3-175:14:writable] Warning: Pure function 'Modelica.Utilities.Strings.isEmpty' contains a call to impure function 'Modelica.Utilities.Strings.Advanced.skipWhiteSpace'. Notification: Performance of NFTyping.typeBindings: time 0.001456/0.01782, allocations: 0.6917 MB / 0.5658 GB, free: 50.81 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:133:3-133:117:writable] Warning: In relation generatorSynchronous.SNom <> generatorSynchronous.PNomAlt, <> on Real numbers is only allowed inside functions. Notification: Performance of NFTyping.typeClassSections: time 0.002905/0.02072, allocations: 1.958 MB / 0.5677 GB, free: 49.67 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:51:3-51:114:writable] Error: Parameter generatorSynchronous.MdPPuEfd has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:52:3-52:139:writable] Error: Parameter generatorSynchronous.MdPPuEfdNom has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Types.mo:49:35-49:96:writable] Error: Parameter generatorSynchronous.s0Pu.re has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Types.mo:50:35-50:101:writable] Error: Parameter generatorSynchronous.s0Pu.im has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Types.mo:49:35-49:96:writable] Error: Parameter generatorSynchronous.sStator0Pu.re has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Types.mo:50:35-50:101:writable] Error: Parameter generatorSynchronous.sStator0Pu.im has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Types.mo:49:35-49:96:writable] Error: Parameter generatorSynchronous.uStator0Pu.re has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Types.mo:50:35-50:101:writable] Error: Parameter generatorSynchronous.uStator0Pu.im has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Types.mo:49:35-49:96:writable] Error: Parameter generatorSynchronous.iStator0Pu.re has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Types.mo:50:35-50:101:writable] Error: Parameter generatorSynchronous.iStator0Pu.im has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:58:3-58:119:writable] Error: Parameter generatorSynchronous.QStator0PuQNom has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Steam/GovSteam1.mo:48:3-49:25:writable] Error: Parameter governor.PgvTableName has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Steam/GovSteam1.mo:50:3-51:141:writable] Error: Parameter governor.TablesFile has neither value nor start value, and is fixed during initialization (fixed=true). Notification: Performance of NFFlatten.flatten: time 0.004321/0.02504, allocations: 4.848 MB / 0.5724 GB, free: 47.36 MB / 462.1 MB Notification: Performance of NFFlatten.resolveConnections: time 0.001214/0.02626, allocations: 0.6495 MB / 0.5731 GB, free: 46.92 MB / 462.1 MB Notification: Performance of NFEvalConstants.evaluate: time 0.002138/0.02839, allocations: 1.56 MB / 0.5746 GB, free: 46.13 MB / 462.1 MB Notification: Performance of NFSimplifyModel.simplify: time 0.00175/0.03014, allocations: 1.364 MB / 0.5759 GB, free: 45.4 MB / 462.1 MB Notification: Performance of NFPackage.collectConstants: time 0.0004603/0.0306, allocations: 292 kB / 0.5762 GB, free: 45.4 MB / 462.1 MB Notification: Performance of NFFlatten.collectFunctions: time 0.0009313/0.03154, allocations: 0.5052 MB / 0.5767 GB, free: 45.33 MB / 462.1 MB Notification: Performance of combineBinaries: time 0.00399/0.03552, allocations: 5.229 MB / 0.5818 GB, free: 41.66 MB / 462.1 MB Notification: Performance of replaceArrayConstructors: time 0.002612/0.03814, allocations: 3.176 MB / 0.5849 GB, free: 39.4 MB / 462.1 MB Notification: Performance of NFVerifyModel.verify: time 0.0009507/0.03909, allocations: 132.4 kB / 0.585 GB, free: 39.4 MB / 462.1 MB Notification: Performance of FrontEnd: time 0.0008086/0.0399, allocations: 114.2 kB / 0.5851 GB, free: 39.35 MB / 462.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 3.0389794632792473] Failed to read output from testmodel.py, exit status != 0: 0.2626802888698876 0.07001773800000001 0.027306077 Calling exit ...