Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariable.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/package.mo", uses=false) Using package Buildings with version 9.1.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariable,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|zon.TAir|equEle.y",fileNamePrefix="Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariable") translateModel(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariable,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|zon.TAir|equEle.y",fileNamePrefix="Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariable") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001152/0.001152, allocations: 111.2 kB / 16.43 MB, free: 6.461 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001104/0.001104, allocations: 185.5 kB / 17.36 MB, free: 5.73 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.159/1.159, allocations: 222.9 MB / 241 MB, free: 15.14 MB / 206.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/package.mo): time 1.931/1.931, allocations: 390.2 MB / 0.6655 GB, free: 0.6562 MB / 0.5294 GB Notification: Performance of FrontEnd - Absyn->SCode: time 1.984e-05/1.985e-05, allocations: 4.672 kB / 0.9515 GB, free: 7.695 MB / 0.7325 GB Notification: Performance of NFInst.instantiate(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariable): time 0.5843/0.5843, allocations: 179.6 MB / 1.127 GB, free: 5.512 MB / 0.8575 GB Notification: Performance of NFInst.instExpressions: time 0.01604/0.6004, allocations: 14.71 MB / 1.141 GB, free: 4.082 MB / 0.8575 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.002291/0.6028, allocations: 48.72 kB / 1.141 GB, free: 4.062 MB / 0.8575 GB Notification: Performance of NFTyping.typeComponents: time 0.001517/0.6043, allocations: 0.6429 MB / 1.142 GB, free: 3.797 MB / 0.8575 GB Notification: Performance of NFTyping.typeBindings: time 0.00501/0.6093, allocations: 1.986 MB / 1.144 GB, free: 3.297 MB / 0.8575 GB Notification: Performance of NFTyping.typeClassSections: time 0.004471/0.6138, allocations: 1.897 MB / 1.146 GB, free: 3.09 MB / 0.8575 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFComponentRef.mo:584:7-587:102:writable] Error: Internal error NFComponentRef.mergeSubscripts failed because the subscripts {$i1} could not be fully merged onto zon.senMasFlo.Medium.nXi. Result: zon.senMasFlo.Medium.nXi with leftover: {$i1}.