Environment - simulationEnvironment: startTime=0 stopTime=100 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.04 Regular simulation: ./Buildings_12_Buildings.Fluid.FixedResistances.Validation.FlowJunctionSteadyState -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00380015s reading init.xml | | | | | | 0.000229621s reading info.xml | | | | | | 0.000409528s [ 1.8%] pre-initialization | | | | | | 0.000209553s [ 0.9%] initialization | | | | | | 3.026e-06s [ 0.0%] steps | | | | | | 0.000940025s [ 4.1%] solver (excl. callbacks) | | | | | | 0.00104826s [ 4.6%] creating output-file | | | | | | 0.0100768s [ 44.1%] event-handling | | | | | | 0.00297919s [ 13.1%] overhead | | | | | | 0.0071626s [ 31.4%] simulation | | | | | | 0.022829s [100.0%] total | | | | | events | | | | | | 6 state events | | | | | | 4 time events | | | | | solver: dassl | | | | | | 294 steps taken | | | | | | 404 calls of functionODE | | | | | | 169 evaluations of jacobian | | | | | | 25 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000242903s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.