Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_1.6_Buildings.Fluid.HeatExchangers.Examples.DryEffectivenessNTU.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/package.mo", uses=false) Using package Buildings with version 1.6 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(Buildings.Fluid.HeatExchangers.Examples.DryEffectivenessNTU,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_1.6_Buildings.Fluid.HeatExchangers.Examples.DryEffectivenessNTU") translateModel(Buildings.Fluid.HeatExchangers.Examples.DryEffectivenessNTU,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_1.6_Buildings.Fluid.HeatExchangers.Examples.DryEffectivenessNTU") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001243/0.001243, allocations: 105.8 kB / 16.42 MB, free: 6.52 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001035/0.001035, allocations: 192.3 kB / 17.35 MB, free: 5.73 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.337/1.337, allocations: 205.1 MB / 223.2 MB, free: 12.24 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/package.mo): time 0.4304/0.4304, allocations: 95.48 MB / 366.1 MB, free: 12.15 MB / 318.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 2.429e-05/2.437e-05, allocations: 2.281 kB / 0.5042 GB, free: 11.9 MB / 398.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/Media/ConstantPropertyLiquidWater/package.mo:15:5-15:61:writable] Error: Found imported name 'simpleWaterConstants' while looking up composite name 'Modelica.Media.Water.simpleWaterConstants'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Fluid/Sources.mo:728:5-728:56:writable] Error: Class Medium.BaseProperties not found in scope PartialSource.