Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=7200 tolerance=1e-06 numberOfIntervals=2500 stepSize=2.88 Regular simulation: ./TransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressor -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt" LOG_STDOUT | info | TILMedia-Error(TestValveAndCompressor.storage.storage.gasBulk, PRModel::TDew, mediumPointerID=0): Dew temperature calculation failed for p=100000, xi={0.72209, 0.139592, 0.0690145, 0.0192457, 0.0266501, 0.0234078, 2.08167e-17, }, Debug info: {D=0.10018, S=1000, dSdT=-1264.15, counter=100} LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STDOUT | info | ##IDA## -4 error occurred at time = 1.23488318711886e-05 LOG_STDOUT | info | model terminate | Integrator failed. | Simulation terminated at time 1.23488e-05 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.135602s reading init.xml | | | | | | 0.012329s reading info.xml | | | | | | 0.00039442s [ 0.4%] pre-initialization | | | | | | 0.0652736s [ 59.9%] initialization | | | | | | 0.0430757s [ 39.5%] steps | | | | | | 0.0635619s [ 58.4%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 3.697e-06s [ 0.0%] event-handling | | | | | | 2.1901e-05s [ 0.0%] overhead | | | | | | -0.0634097s [-58.2%] simulation | | | | | | 0.108922s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 13 steps taken | | | | | | 74 calls of functionODE | | | | | | 31 evaluations of jacobian | | | | | | 1 error test failures | | | | | | 19 convergence test failures | | | | | | 0.0378655s time of jacobian evaluation