Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=100 stepSize=0.01 Regular simulation: ./ThermofluidStream_dev_ThermofluidStream.Idealized.Tests.Processes.Adiabatic.cpSpec -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/AdiabaticThermodynamicModels/PerfectGas.mo:32:5-34:22:writable] | | | | The following assertion has been violated at time 1.000000 | | | | ((noEvent(pefectGasState.adiabaticModel.delta_cp_rel < 0.01))) --> "In "cpSpec.pefectGasState.adiabaticModel" the specific isobaric heat capacity varies between inlet and outlet beyond the specified tolerance." LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00183752s reading init.xml | | | | | | 0.000210737s reading info.xml | | | | | | 0.00260685s [ 57.5%] pre-initialization | | | | | | 0.000102703s [ 2.3%] initialization | | | | | | 1.4006e-05s [ 0.3%] steps | | | | | | 1.465e-06s [ 0.0%] solver (excl. callbacks) | | | | | | 0.000128097s [ 2.8%] creating output-file | | | | | | 1.58e-06s [ 0.0%] event-handling | | | | | | 6.7517e-05s [ 1.5%] overhead | | | | | | 0.00161268s [ 35.6%] simulation | | | | | | 0.0045349s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 100 steps taken | | | | | | 100 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.