Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=100 stepSize=0.01 Regular simulation: ./ThermofluidStream_ThermofluidStream.Idealized.Examples.ClausiusRankine.Step2SaturatedVapor -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pump.p_min >= 611.657 and pump.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= pump.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((turbine.p_min >= 611.657 and turbine.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= turbine.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((preheaterAndBoiler.p_min >= 611.657 and preheaterAndBoiler.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= preheaterAndBoiler.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flowResistance.p_min >= 611.657 and flowResistance.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= flowResistance.p_min <= 1e8, has value: 100" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00269652s reading init.xml | | | | | | 0.000247134s reading info.xml | | | | | | 0.00283296s [ 22.4%] pre-initialization | | | | | | 0.000458632s [ 3.6%] initialization | | | | | | 7.3388e-05s [ 0.6%] steps | | | | | | 0.000827515s [ 6.6%] solver (excl. callbacks) | | | | | | 0.000161984s [ 1.3%] creating output-file | | | | | | 0.000127817s [ 1.0%] event-handling | | | | | | 0.000237971s [ 1.9%] overhead | | | | | | 0.00789942s [ 62.6%] simulation | | | | | | 0.0126197s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 323 steps taken | | | | | | 436 calls of functionODE | | | | | | 44 evaluations of jacobian | | | | | | 12 error test failures | | | | | | 1 convergence test failures | | | | | | 5.1202e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.