Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo) Running command: translateModel(ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC,tolerance=0.001,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC") translateModel(ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC,tolerance=0.001,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.8121/0.8121, allocations: 150.9 MB / 167.2 MB, free: 14.49 MB / 142.1 MB Notification: Performance of FrontEnd - loaded program: time 0.0003337/0.0003341, allocations: 13.89 kB / 237.8 MB, free: 1.77 MB / 190.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.05443/0.05478, allocations: 31.35 MB / 269.2 MB, free: 7.012 MB / 222.1 MB Notification: Automatically loaded package Complex 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.0.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC): time 1.756/1.81, allocations: 402.9 MB / 0.6563 GB, free: 0.6406 MB / 0.5294 GB Notification: Performance of NFInst.instExpressions: time 0.6729/2.483, allocations: 250.4 MB / 0.9008 GB, free: 13.18 MB / 0.67 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.026/2.509, allocations: 453.8 kB / 0.9012 GB, free: 12.73 MB / 0.67 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:134:3-135:75:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:136:3-137:75:writable] Warning: Connector Cm is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:138:3-139:77:writable] Warning: Connector Cd is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:140:3-141:65:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:155:3-157:58:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:158:3-159:76:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:160:3-161:66:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:134:3-135:75:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:136:3-137:75:writable] Warning: Connector Cm is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:138:3-139:77:writable] Warning: Connector Cd is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:140:3-141:65:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:155:3-157:58:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:158:3-159:76:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:160:3-161:66:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeB.mo:104:3-105:67:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeB.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeB.mo:109:3-111:57:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeB.mo:112:3-113:75:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:134:3-135:75:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:136:3-137:75:writable] Warning: Connector Cm is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:138:3-139:77:writable] Warning: Connector Cd is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:140:3-141:65:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:155:3-157:58:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:158:3-159:76:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:160:3-161:66:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/SinkP.mo:46:3-47:67:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:65:3-66:54:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:67:3-68:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:72:3-76:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:65:3-66:54:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:67:3-68:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:72:3-76:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:65:3-66:54:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:67:3-68:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:72:3-76:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:43:3-44:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:45:3-46:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:43:3-44:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:45:3-46:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:43:3-44:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:45:3-46:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:119:3-120:52:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:121:3-122:53:writable] Warning: Connector Cl is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:129:3-130:55:writable] Warning: Connector Cee is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:131:3-132:53:writable] Warning: Connector Cse is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/SourceQ.mo:62:3-63:65:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/SinkP.mo:46:3-47:67:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeA.mo:104:3-105:67:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeA.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeA.mo:109:3-110:73:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeA.mo:111:3-112:75:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StaticCentrifugalPump.mo:63:3-64:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StaticCentrifugalPump.mo:65:3-66:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StaticCentrifugalPump.mo:63:3-64:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StaticCentrifugalPump.mo:65:3-66:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:43:3-44:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:45:3-46:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:43:3-44:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:45:3-46:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StaticCentrifugalPump.mo:63:3-64:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StaticCentrifugalPump.mo:65:3-66:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:104:3-105:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:106:3-107:73:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:108:3-109:75:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:110:3-111:71:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/SourceQ.mo:62:3-63:65:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.0221/2.532, allocations: 6.006 MB / 0.9071 GB, free: 6.723 MB / 0.67 GB Notification: Performance of NFTyping.typeBindings: time 0.05185/2.583, allocations: 17.71 MB / 0.9244 GB, free: 4.91 MB / 0.6856 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:783:9-783:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:850:9-850:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:1088:9-1088:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/Fluid/derDensity_derP_derh.mo:63:5-63:84:writable] Warning: T was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:1445:9-1445:35:writable] Warning: h was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ps.mo:71:3-71:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ps.mo:71:3-71:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.099/2.683, allocations: 35.71 MB / 0.9593 GB, free: 1.25 MB / 0.7169 GB Notification: Performance of NFFlatten.flatten: time 0.9666/3.649, allocations: 110.6 MB / 1.067 GB, free: 42.51 MB / 0.7638 GB Notification: Performance of NFFlatten.resolveConnections: time 0.06888/3.718, allocations: 39.29 MB / 1.106 GB, free: 36.52 MB / 0.7638 GB Notification: Performance of NFEvalConstants.evaluate: time 0.07578/3.794, allocations: 36.57 MB / 1.141 GB, free: 16.66 MB / 0.7638 GB Notification: Performance of NFSimplifyModel.simplify: time 0.07472/3.869, allocations: 40.68 MB / 1.181 GB, free: 10.44 MB / 0.795 GB Notification: Performance of NFPackage.collectConstants: time 0.03352/3.902, allocations: 8.307 MB / 1.189 GB, free: 2.137 MB / 0.795 GB Notification: Performance of NFFlatten.collectFunctions: time 0.1076/4.01, allocations: 39.07 MB / 1.227 GB, free: 12.16 MB / 0.8419 GB Notification: Performance of NFScalarize.scalarize: time 0.0456/4.056, allocations: 24.43 MB / 1.251 GB, free: 4.199 MB / 0.8575 GB Notification: Performance of NFVerifyModel.verify: time 0.09032/4.146, allocations: 35.06 MB / 1.285 GB, free: 1.418 MB / 0.8888 GB Notification: Performance of NFConvertDAE.convert: time 0.9884/5.134, allocations: 106.6 MB / 1.39 GB, free: 155.6 MB / 0.9514 GB Notification: Performance of FrontEnd - DAE generated: time 6.042e-06/5.134, allocations: 0 / 1.39 GB, free: 155.6 MB / 0.9514 GB Notification: Performance of FrontEnd: time 1.372e-06/5.134, allocations: 0.8125 kB / 1.39 GB, free: 155.6 MB / 0.9514 GB Notification: Performance of Transformations before backend: time 0.003182/5.137, allocations: 1.656 kB / 1.39 GB, free: 155.6 MB / 0.9514 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 15109 * Number of variables: 15109 Notification: Performance of Generate backend data structure: time 0.2884/5.426, allocations: 71.73 MB / 1.46 GB, free: 136.9 MB / 0.9514 GB Notification: Performance of prepare preOptimizeDAE: time 4.694e-05/5.426, allocations: 8.469 kB / 1.46 GB, free: 136.9 MB / 0.9514 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.03703/5.463, allocations: 6.059 MB / 1.466 GB, free: 133.9 MB / 0.9514 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.06645/5.529, allocations: 24.1 MB / 1.489 GB, free: 128.4 MB / 0.9514 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.02092/5.55, allocations: 15.58 MB / 1.504 GB, free: 116.6 MB / 0.9514 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.029/5.579, allocations: 4.7 MB / 1.509 GB, free: 116.5 MB / 0.9514 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.2552/5.835, allocations: 96.56 MB / 1.603 GB, free: 24.32 MB / 0.9514 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.002247/5.837, allocations: 190.2 kB / 1.603 GB, free: 24.24 MB / 0.9514 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.02735/5.864, allocations: 1.961 MB / 1.605 GB, free: 22.28 MB / 0.9514 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.001333/5.866, allocations: 1.702 MB / 1.607 GB, free: 20.58 MB / 0.9514 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.2964/6.162, allocations: 114.3 MB / 1.719 GB, free: 3.242 MB / 1.045 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.8618/7.024, allocations: 398.5 MB / 2.108 GB, free: 191.6 MB / 1.045 GB Notification: Performance of preOpt comSubExp (simulation): time 0.1751/7.199, allocations: 84.58 MB / 2.19 GB, free: 107 MB / 1.045 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.1187/7.318, allocations: 56.1 MB / 2.245 GB, free: 51.12 MB / 1.045 GB Notification: Performance of preOpt evalFunc (simulation): time 1.779/9.097, allocations: 0.7047 GB / 2.95 GB, free: 416.2 MB / 1.045 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.1732/9.271, allocations: 61.31 MB / 3.01 GB, free: 404.3 MB / 1.045 GB Notification: Performance of pre-optimization done (n=7660): time 9.854e-05/9.271, allocations: 0 / 3.01 GB, free: 404.3 MB / 1.045 GB Notification: Performance of matching and sorting (n=7668): time 1.577/10.85, allocations: 397.3 MB / 3.398 GB, free: 395.1 MB / 1.045 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0006553/10.85, allocations: 1.538 MB / 3.399 GB, free: 393.7 MB / 1.045 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.03091/10.88, allocations: 20.22 MB / 3.419 GB, free: 380.1 MB / 1.045 GB Notification: Performance of collectPreVariables (initialization): time 0.01936/10.9, allocations: 0.7823 MB / 3.42 GB, free: 379.3 MB / 1.045 GB Notification: Performance of collectInitialEqns (initialization): time 0.01356/10.91, allocations: 16.4 MB / 3.436 GB, free: 364.6 MB / 1.045 GB Notification: Performance of collectInitialBindings (initialization): time 0.04093/10.95, allocations: 26.12 MB / 3.461 GB, free: 338.6 MB / 1.045 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.3806/11.33, allocations: 13.14 MB / 3.474 GB, free: 468.9 MB / 1.045 GB Notification: Performance of setup shared object (initialization): time 5.411e-05/11.33, allocations: 305.8 kB / 3.474 GB, free: 468.6 MB / 1.045 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.1306/11.47, allocations: 50.66 MB / 3.524 GB, free: 468.2 MB / 1.045 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.1409/11.61, allocations: 66.2 MB / 3.588 GB, free: 434 MB / 1.045 GB Notification: Performance of analyzeInitialSystem (initialization): time 1.531/13.14, allocations: 335.4 MB / 3.916 GB, free: 391.3 MB / 1.045 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0005594/13.14, allocations: 119.4 kB / 3.916 GB, free: 391.3 MB / 1.045 GB Notification: Performance of matching and sorting (n=10041) (initialization): time 0.9208/14.06, allocations: 170.4 MB / 4.083 GB, free: 408.6 MB / 1.045 GB Notification: Performance of prepare postOptimizeDAE: time 0.0004006/14.06, allocations: 240.5 kB / 4.083 GB, free: 408.5 MB / 1.045 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.001297/14.06, allocations: 0.5244 MB / 4.083 GB, free: 408.5 MB / 1.045 GB Notification: Performance of postOpt tearingSystem (initialization): time 6.604/20.66, allocations: 2.393 GB / 6.477 GB, free: 396.5 MB / 1.045 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.03763/20.7, allocations: 8.107 MB / 6.485 GB, free: 390.7 MB / 1.045 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.9292/21.63, allocations: 184.8 MB / 6.665 GB, free: 413.3 MB / 1.045 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.08519/21.72, allocations: 6.94 MB / 6.672 GB, free: 413.3 MB / 1.045 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.02574/21.74, allocations: 2.986 MB / 6.675 GB, free: 413.3 MB / 1.045 GB Warning: Assuming fixed start value for the following 5 variables: regulation_Niveau_HP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_MP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_BP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real Warning: The initial conditions are over specified. The following 4 initial equations are redundant, so they are removed from the initialization system: $DER.EconomiseurHP4.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SurchauffeurHP2.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SurchauffeurHP3.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SurchauffeurMP3.TwoPhaseFlowPipe.Q[1] = 0.0. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 1905 * Number of states: 0 () * Number of discrete variables: 400 ($PRE.regulation_Niveau_HP.pIsat.Integrateur1.x0,regulation_Niveau_HP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,VolumeAlimMPHP.Cs1.diff_on_2,EconomiseurMP.Cws1.diff_on_1,VolumeAlimMPHP.Cs2.diff_on_2,Vanne_alimentationMPHP1.C2.diff_on_1,CapteurDebitEauCondenseur.C1.diff_on_2,perteChargeK.C2.diff_on_2,vanne_extraction.C2.diff_on_1,perteChargeK2.C2.diff_on_1,SourceFumees.C.ftype,DoubleDebitMP.Cs.ftype,MelangeurPreTMP.Cs.ftype,MelangeurPreTMP.Ce3.ftype,MelangeurPreTMP.Ce2.ftype,MelangeurPreTMP.fluids[1],VolumePreTHP.Cs3.ftype,VolumePreTHP.Cs2.ftype,VolumePreTHP.Cs1.ftype,DoubleDebitHP.Cs.ftype,VolumePreTHP.fluids[1],VolumeAlimMPHP.Cs1.ftype,VolumeAlimMPHP.Cs2.ftype,VolumeECO_HP2_3.Cs.ftype,VolumeECO_HP2_3.Ce3.ftype,VolumeECO_HP2_3.Ce2.ftype,VolumeECO_HP1_2.Cs.ftype,VolumeECO_HP2_3.fluids[1],VolumeECO_HP1_2.Ce3.ftype,VolumeECO_HP1_2.Ce2.ftype,VolumeECO_HP1_2.fluids[1],regulation_Niveau_Condenseur.pIsat.Integrateur1.reset.signal,regulation_Niveau_BP.pIsat.Integrateur1.reset.signal,regulation_Niveau_MP.pIsat.Integrateur1.reset.signal,regulation_Niveau_HP.pIsat.Integrateur1.reset.signal,MelangeurHPMP.Cs2.ftype,MelangeurPostTMP1.Cs.ftype,Condenseur.Cl.ftype,BallonBP.Cs.ftype,VolumeCond1.Cs.ftype,BallonBP.Cv.ftype,BallonMP.Cv.ftype,BallonHP.Cv.ftype,DoubleDebitBP.Cs.ftype,DoubleDebitBP.fluids[1],MoitieDebitBP.Cs.ftype,MoitieDebitBP.fluids[1],VolumeAlimMPHP.Ce2.ftype,VolumeAlimMPHP.fluids[1],VolumeCond1.Ce2.ftype,VolumeCond1.Ce1.ftype,VolumeCond1.fluids[1],SourceCaloporteur.C.ftype,MoitieDebitHP.Cs.ftype,MoitieDebitHP.fluids[1],DoubleDebitMP.fluids[1],DoubleDebitHP.fluids[1],MelangeurPostTMP1.Ce3.ftype,MelangeurPostTMP1.fluids[1],VolumeEvapBP.Cs.ftype,VolumeEvapBP.Ce3.ftype,VolumeEvapBP.Ce2.ftype,BallonBP.Cd.ftype,VolumeEvapBP.fluids[1],BallonBP.Ce3.ftype,BallonBP.Ce2.ftype,BallonBP.fluids[1],MelangeurHPMP.Cs1.ftype,MelangeurHPMP.fluids[1],VolumeEvapMP.Cs.ftype,VolumeEvapMP.Ce3.ftype,VolumeEvapMP.Ce2.ftype,BallonMP.Cd.ftype,VolumeEvapMP.fluids[1],BallonMP.Cs.ftype,BallonMP.Ce3.ftype,BallonMP.Ce2.ftype,BallonMP.fluids[1],VolumeEvapHP.Cs.ftype,VolumeEvapHP.Ce3.ftype,VolumeEvapHP.Ce2.ftype,BallonHP.Cd.ftype,VolumeEvapHP.fluids[1],BallonHP.Cs.ftype,BallonHP.Ce3.ftype,BallonHP.Ce2.ftype,BallonHP.fluids[1],vanne_alimentationHP.fluid,vanne_vapeurHP.fluid,GainChargeHP.fluid,EvaporateurHP.ExchangerFlueGasesMetal.fluid,EvaporateurHP.TwoPhaseFlowPipe.fluid,EconomiseurHP4.ExchangerFlueGasesMetal.fluid,EconomiseurHP4.TwoPhaseFlowPipe.fluid,SurchauffeurHP1.ExchangerFlueGasesMetal.fluid,SurchauffeurHP1.TwoPhaseFlowPipe.fluid,EconomiseurHP3.ExchangerFlueGasesMetal.fluid,EconomiseurHP3.TwoPhaseFlowPipe.fluid,EconomiseurHP2.ExchangerFlueGasesMetal.fluid,EconomiseurHP2.TwoPhaseFlowPipe.fluid,EconomiseurHP1.ExchangerFlueGasesMetal.fluid,EconomiseurHP1.TwoPhaseFlowPipe.fluid,SurchauffeurHP2.ExchangerFlueGasesMetal.fluid,SurchauffeurHP2.TwoPhaseFlowPipe.fluid,SurchauffeurHP3.ExchangerFlueGasesMetal.fluid,SurchauffeurHP3.TwoPhaseFlowPipe.fluid,vanne_alimentationMP.fluid,vanne_vapeurMP.fluid,EvaporateurMP.ExchangerFlueGasesMetal.fluid,EvaporateurMP.TwoPhaseFlowPipe.fluid,GainChargeMP.fluid,EconomiseurMP.ExchangerFlueGasesMetal.fluid,EconomiseurMP.TwoPhaseFlowPipe.fluid,SurchauffeurMP1.ExchangerFlueGasesMetal.fluid,SurchauffeurMP1.TwoPhaseFlowPipe.fluid,SurchauffeurMP2.ExchangerFlueGasesMetal.fluid,SurchauffeurMP2.TwoPhaseFlowPipe.fluid,SurchauffeurMP3.ExchangerFlueGasesMetal.fluid,SurchauffeurMP3.TwoPhaseFlowPipe.fluid,vanne_vapeurBP.fluid,vanne_alimentationBP.fluid,GainChargeBP.fluid,EvaporateurBP.ExchangerFlueGasesMetal.fluid,EvaporateurBP.TwoPhaseFlowPipe.fluid,Vanne_alimentationMPHP.fluid,SurchauffeurBP.ExchangerFlueGasesMetal.fluid,SurchauffeurBP.TwoPhaseFlowPipe.fluid,PuitsFumees.fluid,EconomiseurBP.ExchangerFlueGasesMetal.fluid,EconomiseurBP.TwoPhaseFlowPipe.fluid,TurbineHP.fluid,TurbineMP.fluid,TurbineBP.fluid,Condenseur.fluid_p,PuitsCaloporteur.fluid,perteChargeK1.fluid,perteChargeKCond1.fluid,PompeAlimMP.fluid,PompeAlimHP.fluid,PerteChargeZero2.fluid,perteChargeK3.fluid,perteChargeK8.fluid,perteChargeK.fluid,PompeAlimBP.fluid,perteChargeK2.fluid,vanne_extraction.fluid,lumpedStraightPipeK2.fluid,vanne_entree_TurbineHP.fluid,Vanne_alimentationMPHP1.fluid,Vanne_alimentationMPHP2.fluid,vanne_entree_TurbineMP.fluid,regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal,$PRE.regulation_Niveau_Condenseur.edge.uL.signal,$whenCondition1,SourceFumees.fluid1,MelangeurPreTMP.fluid1,VolumePreTHP.fluid1,VolumeECO_HP2_3.fluid1,VolumeECO_HP1_2.fluid1,DoubleDebitBP.fluid1,MoitieDebitBP.fluid1,VolumeAlimMPHP.fluid1,VolumeCond1.fluid1,SourceCaloporteur.fluid1,MoitieDebitHP.fluid1,DoubleDebitMP.fluid1,DoubleDebitHP.fluid1,MelangeurPostTMP1.fluid1,VolumeEvapBP.fluid1,MelangeurHPMP.fluid1,VolumeEvapMP.fluid1,VolumeEvapHP.fluid1,MelangeurPreTMP.Ce1.diff_on_2,DoubleDebitMP.Cs.diff_on_2,DoubleDebitMP.Cs.diff_on_1,vanne_entree_TurbineMP.C2.diff_on_1,MelangeurPreTMP.Cs.diff_on_1,TurbineMP.Cs.diff_on_1,MelangeurPreTMP.Ce3.diff_on_2,MelangeurPreTMP.Ce2.diff_on_2,MelangeurPreTMP.Ce3.diff_on_1,MelangeurPreTMP.Ce2.diff_on_1,VolumePreTHP.Cs3.diff_on_1,TurbineHP.Cs.diff_on_1,VolumePreTHP.Cs2.diff_on_1,VolumePreTHP.Cs1.diff_on_1,VolumePreTHP.Ce.diff_on_2,DoubleDebitHP.Cs.diff_on_2,VolumePreTHP.Cs2.diff_on_2,VolumePreTHP.Cs1.diff_on_2,EconomiseurMP.TwoPhaseFlowPipe.C1.diff_on_2,PompeAlimMP.C2.diff_on_2,perteChargeK8.C2.diff_on_2,VolumeAlimMPHP.Cs1.diff_on_1,perteChargeK8.C2.diff_on_1,PompeAlimMP.C2.diff_on_1,EconomiseurHP1.TwoPhaseFlowPipe.C1.diff_on_2,Vanne_alimentationMPHP1.C1.diff_on_2,perteChargeK3.C2.diff_on_2,VolumeAlimMPHP.Cs2.diff_on_1,perteChargeK3.C2.diff_on_1,Vanne_alimentationMPHP1.C1.diff_on_1,VolumeECO_HP2_3.Cs.diff_on_1,VolumeECO_HP2_3.Ce3.diff_on_2,VolumeECO_HP2_3.Ce2.diff_on_2,VolumeECO_HP2_3.Ce1.diff_on_2,VolumeECO_HP2_3.Ce3.diff_on_1,VolumeECO_HP2_3.Ce2.diff_on_1,VolumeECO_HP1_2.Cs.diff_on_1,VolumeECO_HP1_2.Ce3.diff_on_2,VolumeECO_HP1_2.Ce2.diff_on_2,VolumeECO_HP1_2.Ce1.diff_on_2,VolumeECO_HP1_2.Ce3.diff_on_1,VolumeECO_HP1_2.Ce2.diff_on_1,DoubleDebitHP.Cs.diff_on_1,vanne_entree_TurbineHP.C2.diff_on_1,SurchauffeurMP2.TwoPhaseFlowPipe.C1.diff_on_2,lumpedStraightPipeK2.C1.diff_on_2,MelangeurHPMP.Cs2.diff_on_1,SurchauffeurMP2.Cws1.diff_on_1,Condenseur.Cv.diff_on_2,TurbineBP.Cs.diff_on_2,MelangeurPostTMP1.Cs.diff_on_2,MelangeurPostTMP1.Cs.diff_on_1,TurbineBP.Cs.diff_on_1,CapteurDebitVapCondenseur.C2.diff_on_1,MoitieDebitBP.Ce.diff_on_2,vanne_extraction.C2.diff_on_2,PompeAlimBP.C2.diff_on_2,Condenseur.Cl.diff_on_1,perteChargeK.C2.diff_on_1,PompeAlimBP.C2.diff_on_1,VolumeAlimMPHP.Ce1.diff_on_2,CapteurDebitEauBPsortie.C1.diff_on_2,BallonBP.Cs.diff_on_1,Vanne_alimentationMPHP.C2.diff_on_1,BallonBP.Ce1.diff_on_2,CapteurDebitEauBP.C1.diff_on_2,EconomiseurBP.TwoPhaseFlowPipe.C2.diff_on_1,BallonBP.Ce1.diff_on_1,SurchauffeurBP.TwoPhaseFlowPipe.C1.diff_on_2,vanne_vapeurBP.C1.diff_on_2,BallonBP.Cv.diff_on_1,CapteurDebitVapBP.C2.diff_on_1,SurchauffeurMP1.TwoPhaseFlowPipe.C1.diff_on_2,vanne_vapeurMP.C1.diff_on_2,BallonMP.Cv.diff_on_1,CapteurDebitVapMP.C2.diff_on_1,BallonMP.Ce1.diff_on_2,CapteurDebitEauMP.C1.diff_on_2,EconomiseurMP.TwoPhaseFlowPipe.C2.diff_on_1,BallonMP.Ce1.diff_on_1,BallonHP.Ce1.diff_on_2,CapteurDebitEauHP.C1.diff_on_2,EconomiseurHP4.TwoPhaseFlowPipe.C2.diff_on_1,BallonHP.Ce1.diff_on_1,SurchauffeurHP1.TwoPhaseFlowPipe.C1.diff_on_2,vanne_vapeurHP.C1.diff_on_2,BallonHP.Cv.diff_on_1,CapteurDebitVapHP.C2.diff_on_1,MelangeurPostTMP1.Ce2.diff_on_2,DoubleDebitBP.Cs.diff_on_2,DoubleDebitBP.Cs.diff_on_1,MelangeurPostTMP1.Ce2.diff_on_1,DoubleDebitBP.Ce.diff_on_2,MoitieDebitBP.Cs.diff_on_1,VolumeAlimMPHP.Ce2.diff_on_2,VolumeAlimMPHP.Ce2.diff_on_1,EconomiseurBP.TwoPhaseFlowPipe.C1.diff_on_2,VolumeCond1.Cs.diff_on_2,VolumeCond1.Cs.diff_on_1,EconomiseurBP.Cws1.diff_on_1,VolumeCond1.Ce3.diff_on_2,VolumeCond1.Ce2.diff_on_2,VolumeCond1.Ce1.diff_on_2,VolumeCond1.Ce2.diff_on_1,VolumeCond1.Ce1.diff_on_1,MoitieDebitHP.Cs.diff_on_1,MoitieDebitHP.Ce.diff_on_2,VolumePreTHP.Cs3.diff_on_2,DoubleDebitMP.Ce.diff_on_2,DoubleDebitHP.Ce.diff_on_2,MelangeurPostTMP1.Ce3.diff_on_2,MelangeurPostTMP1.Ce1.diff_on_2,MelangeurPreTMP.Cs.diff_on_2,MelangeurPostTMP1.Ce3.diff_on_1,EconomiseurBP.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurBP.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurBP.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurBP.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurBP.ExchangerFlueGasesMetal.C2.diff_on_1,EvaporateurBP.TwoPhaseFlowPipe.C1.diff_on_2,EvaporateurBP.TwoPhaseFlowPipe.C2.diff_on_1,EvaporateurBP.ExchangerFlueGasesMetal.C1.diff_on_2,EvaporateurBP.ExchangerFlueGasesMetal.C2.diff_on_1,VolumeEvapBP.Cs.diff_on_1,VolumeEvapBP.Ce3.diff_on_2,VolumeEvapBP.Ce2.diff_on_2,VolumeEvapBP.Ce1.diff_on_2,BallonBP.Cd.diff_on_2,VolumeEvapBP.Ce3.diff_on_1,VolumeEvapBP.Ce2.diff_on_1,BallonBP.Cd.diff_on_1,VolumeEvapBP.Ce1.diff_on_1,BallonBP.Cm.diff_on_2,BallonBP.Ce3.diff_on_2,BallonBP.Ce2.diff_on_2,BallonBP.Ce3.diff_on_1,BallonBP.Ce2.diff_on_1,SurchauffeurMP3.TwoPhaseFlowPipe.C1.diff_on_2,SurchauffeurMP3.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurMP3.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurMP3.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurMP2.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurMP2.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurMP2.ExchangerFlueGasesMetal.C2.diff_on_1,MelangeurHPMP.Cs1.diff_on_1,MelangeurHPMP.Ce2.diff_on_2,MelangeurHPMP.Ce1.diff_on_2,MelangeurHPMP.Cs1.diff_on_2,SurchauffeurMP1.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurMP1.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurMP1.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurMP.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurMP.ExchangerFlueGasesMetal.C2.diff_on_1,VolumeEvapMP.Cs.diff_on_1,VolumeEvapMP.Ce3.diff_on_2,VolumeEvapMP.Ce2.diff_on_2,VolumeEvapMP.Ce1.diff_on_2,GainChargeMP.C1.diff_on_2,VolumeEvapMP.Ce3.diff_on_1,VolumeEvapMP.Ce2.diff_on_1,BallonMP.Cd.diff_on_1,VolumeEvapMP.Ce1.diff_on_1,EvaporateurMP.TwoPhaseFlowPipe.C1.diff_on_2,EvaporateurMP.TwoPhaseFlowPipe.C2.diff_on_1,EvaporateurMP.ExchangerFlueGasesMetal.C1.diff_on_2,EvaporateurMP.ExchangerFlueGasesMetal.C2.diff_on_1,BallonMP.Cs.diff_on_1,BallonMP.Cm.diff_on_2,BallonMP.Ce3.diff_on_2,BallonMP.Ce2.diff_on_2,BallonMP.Cs.diff_on_2,BallonMP.Ce3.diff_on_1,BallonMP.Ce2.diff_on_1,SurchauffeurHP3.TwoPhaseFlowPipe.C1.diff_on_2,SurchauffeurHP3.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurHP3.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurHP3.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurHP2.TwoPhaseFlowPipe.C1.diff_on_2,SurchauffeurHP2.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurHP2.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurHP2.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurHP1.TwoPhaseFlowPipe.C2.diff_on_1,EconomiseurHP1.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurHP1.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurHP2.TwoPhaseFlowPipe.C1.diff_on_2,EconomiseurHP2.TwoPhaseFlowPipe.C2.diff_on_1,EconomiseurHP2.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurHP2.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurHP3.TwoPhaseFlowPipe.C1.diff_on_2,EconomiseurHP3.TwoPhaseFlowPipe.C2.diff_on_1,EconomiseurHP3.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurHP3.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurHP1.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurHP1.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurHP1.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurHP4.TwoPhaseFlowPipe.C1.diff_on_2,EconomiseurHP4.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurHP4.ExchangerFlueGasesMetal.C2.diff_on_1,EvaporateurHP.TwoPhaseFlowPipe.C1.diff_on_2,EvaporateurHP.TwoPhaseFlowPipe.C2.diff_on_1,EvaporateurHP.ExchangerFlueGasesMetal.C1.diff_on_2,EvaporateurHP.ExchangerFlueGasesMetal.C2.diff_on_1,VolumeEvapHP.Cs.diff_on_1,VolumeEvapHP.Ce3.diff_on_2,VolumeEvapHP.Ce2.diff_on_2,VolumeEvapHP.Ce1.diff_on_2,GainChargeHP.C1.diff_on_2,VolumeEvapHP.Ce3.diff_on_1,VolumeEvapHP.Ce2.diff_on_1,BallonHP.Cd.diff_on_1,VolumeEvapHP.Ce1.diff_on_1,BallonHP.Cs.diff_on_1,BallonHP.Cm.diff_on_2,BallonHP.Ce3.diff_on_2,BallonHP.Ce2.diff_on_2,BallonHP.Cs.diff_on_2,BallonHP.Ce3.diff_on_1,BallonHP.Ce2.diff_on_1) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (3642): * Single equations (assignments): 3589 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 34 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 5 * Torn equation systems: 12 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 5 systems {1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 1 system {(4,1,62.5%)} * Non-linear torn systems (#iteration vars, #inner vars): 11 systems {(1,1), (1,5), (2,11), (1,15), (1,1), (1,15), (305,2988), (1,1), (1,1), (1,1), (1,1)} Notification: Performance of prepare postOptimizeDAE: time 0.07397/21.82, allocations: 12.75 MB / 6.687 GB, free: 413.1 MB / 1.045 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.03163/21.85, allocations: 3.956 MB / 6.691 GB, free: 413.1 MB / 1.045 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.531/22.38, allocations: 164.6 MB / 6.852 GB, free: 362.2 MB / 1.045 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.001901/22.38, allocations: 234.2 kB / 6.852 GB, free: 361.9 MB / 1.045 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.000738/22.38, allocations: 122.3 kB / 6.852 GB, free: 361.9 MB / 1.045 GB Notification: Performance of postOpt removeConstants (simulation): time 0.0539/22.44, allocations: 13.98 MB / 6.866 GB, free: 354 MB / 1.045 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.02839/22.46, allocations: 0.9923 MB / 6.867 GB, free: 353.3 MB / 1.045 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.07059/22.53, allocations: 6.241 MB / 6.873 GB, free: 349.4 MB / 1.045 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.02978/22.56, allocations: 4.045 MB / 6.877 GB, free: 345.3 MB / 1.045 GB [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/BackEnd/DAEMode.mo:528:7-530:90:writable] Error: Internal error DAEMode.traverserStrongComponents failed on equation: 1/1 (10): ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_ph(TurbineBP.Te, TurbineBP.proe.d, TurbineBP.proe.u, TurbineBP.proe.s, TurbineBP.proe.cp, TurbineBP.proe.ddhp, TurbineBP.proe.ddph, TurbineBP.proe.duph, TurbineBP.proe.duhp, TurbineBP.proe.x) = $cse304 Variables: 1: TurbineBP.Te:VARIABLE(min = 200.0 max = 6000.0 start = 288.15 unit = "K" nominal = 300.0 ) "Temperature at the inlet" type: Real 2: TurbineBP.proe.duhp:VARIABLE(unit = "1" ) "Derivative of specific inner energy wrt. specific enthalpy at constant pressure" type: Real 3: TurbineBP.proe.u:VARIABLE(min = -1e8 max = 1e8 unit = "J/kg" nominal = 1e6 ) "Specific inner energy" type: Real 4: TurbineBP.proe.cp:VARIABLE(min = 1e-9 max = 1e60 unit = "J/(kg.K)" nominal = 1000.0 ) "Specific heat capacity at constant presure" type: Real 5: TurbineMP.proe.ddph:VARIABLE(unit = "s2/m2" ) "Derivative of density wrt. pressure at constant specific enthalpy" type: Real 6: TurbineMP.proe.cp:VARIABLE(min = 1e-9 max = 1e60 unit = "J/(kg.K)" nominal = 1000.0 ) "Specific heat capacity at constant presure" type: Real 7: TurbineMP.proe.duhp:VARIABLE(unit = "1" ) "Derivative of specific inner energy wrt. specific enthalpy at constant pressure" type: Real 8: TurbineMP.proe.u:VARIABLE(min = -1e8 max = 1e8 unit = "J/kg" nominal = 1e6 ) "Specific inner energy" type: Real 9: TurbineMP.proe.s:VARIABLE(min = -1e6 max = 1e6 unit = "J/(kg.K)" nominal = 1000.0 ) "Specific entropy" type: Real 10: TurbineMP.Te:VARIABLE(min = 200.0 max = 6000.0 start = 288.15 unit = "K" nominal = 300.0 ) "Temperature at the inlet" type: Real [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/BackEnd/DAEMode.mo:528:7-530:90:writable] Error: Internal error DAEMode.traverserStrongComponents failed on equation: 1/1 (1): TurbineMP.Q = if noEvent(MelangeurPreTMP.P > TurbineMP.pcrit) or noEvent(TurbineMP.Te > TurbineMP.Tcrit) then sqrt((MelangeurPreTMP.P ^ 2.0 - TurbineBP.Pe ^ 2.0) / (TurbineMP.Cst * TurbineMP.Te)) else sqrt((MelangeurPreTMP.P ^ 2.0 - TurbineBP.Pe ^ 2.0) / (TurbineMP.Cst * TurbineMP.Te * TurbineMP.proe.x)) 2/2 (10): $cse304 = ThermoSysPro.Properties.Fluid.Ph(TurbineBP.Pe, MelangeurPostTMP1.Cs.h, TurbineBP.mode_e, TurbineBP.fluid) 3/12 (8): $cse306 = ThermoSysPro.Properties.Fluid.Ps(TurbineBP.Ps, TurbineBP.proe.s, TurbineBP.mode_ps, TurbineBP.fluid) 4/20 (8): ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_ps(TurbineBP.props.T, TurbineBP.props.d, TurbineBP.props.u, TurbineBP.His, TurbineBP.props.cp, TurbineBP.props.ddsp, TurbineBP.props.ddps, TurbineBP.props.x) = $cse306 5/28 (1): TurbineBP.Hrs - MelangeurPostTMP1.Cs.h = TurbineBP.xm * TurbineBP.eta_is * (TurbineBP.His - MelangeurPostTMP1.Cs.h) 6/29 (1): TurbineBP.xm = if noEvent(TurbineBP.Pe > TurbineBP.pcrit) or noEvent(TurbineBP.Te > TurbineBP.Tcrit) then 1.0 else 0.5 * (TurbineBP.proe.x + TurbineBP.pros1.x) 7/30 (10): TurbineBP.pros1 = ThermoSysPro.Properties.Fluid.Ph(TurbineBP.Ps, TurbineBP.Hrs, TurbineBP.mode_s, TurbineBP.fluid) 8/40 (10): $cse305 = ThermoSysPro.Properties.Fluid.Ph(TurbineBP.Ps, perteChargeK1.h, TurbineBP.mode_s, TurbineBP.fluid) 9/50 (10): ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_ph(TurbineBP.Ts, TurbineBP.rhos, TurbineBP.pros.u, TurbineBP.pros.s, TurbineBP.pros.cp, TurbineBP.pros.ddhp, TurbineBP.pros.ddph, TurbineBP.pros.duph, TurbineBP.pros.duhp, TurbineBP.pros.x) = $cse305 10/60 (1): TurbineBP.Vs = perteChargeK1.Q / (TurbineBP.rhos * TurbineBP.area_nz) 11/61 (1): perteChargeK1.h - TurbineBP.Hrs = 0.5 * (1.0 - TurbineBP.eta_nz) * TurbineBP.Vs ^ 2.0 12/62 (1): perteChargeK1.Pm = 0.5 * (TurbineBP.Ps + Condenseur.P) 13/63 (1): perteChargeK1.rho = ThermoSysPro.Properties.Fluid.Density_Ph(perteChargeK1.Pm, perteChargeK1.h, perteChargeK1.fluid, perteChargeK1.mode, 0.0, 0.0, 0.0, 0.0) 14/64 (1): perteChargeK1.deltaP = TurbineBP.Ps - Condenseur.P 15/65 (1): perteChargeK1.deltaP = perteChargeK1.deltaPf + perteChargeK1.deltaPg 16/66 (1): perteChargeK1.deltaPf = perteChargeK1.K * $cse311 / perteChargeK1.rho 17/67 (1): perteChargeK1.deltaPg = 9.80665 * perteChargeK1.rho * (perteChargeK1.z2 - perteChargeK1.z1) 18/68 (1): perteChargeK1.Q = if noEvent(TurbineBP.Pe > TurbineBP.pcrit) or noEvent(TurbineBP.Te > TurbineBP.Tcrit) then sqrt((TurbineBP.Pe ^ 2.0 - TurbineBP.Ps ^ 2.0) / (TurbineBP.Cst * TurbineBP.Te)) else sqrt((TurbineBP.Pe ^ 2.0 - TurbineBP.Ps ^ 2.0) / (TurbineBP.Cst * TurbineBP.Te * TurbineBP.proe.x)) 19/69 (1): $cse311 = ThermoSysPro.Functions.ThermoSquare(perteChargeK1.Q, perteChargeK1.eps) 20/70 (1): TurbineBP.eta_is = if perteChargeK1.Q < TurbineBP.Qmax then max(TurbineBP.eta_is_min, TurbineBP.a * (perteChargeK1.Q / TurbineBP.Qmax) ^ 2.0 + TurbineBP.b * perteChargeK1.Q / TurbineBP.Qmax + TurbineBP.c) else TurbineBP.eta_is_nom 21/71 (1): MelangeurPostTMP1.Cs.h = if perteChargeK1.Q > 0.0 then MelangeurPostTMP1.h else Condenseur.hv 22/72 (1): 0.0 = TurbineMP.Q + PerteChargeZero2.Q - perteChargeK1.Q 23/73 (1): MelangeurPreTMP.Cs.h = if TurbineMP.Q > 0.0 then MelangeurPreTMP.h else MelangeurPostTMP1.h 24/74 (10): $cse301 = ThermoSysPro.Properties.Fluid.Ph(MelangeurPreTMP.P, MelangeurPreTMP.Cs.h, TurbineMP.mode_e, TurbineMP.fluid) 25/84 (10): ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_ph(TurbineMP.Te, TurbineMP.proe.d, TurbineMP.proe.u, TurbineMP.proe.s, TurbineMP.proe.cp, TurbineMP.proe.ddhp, TurbineMP.proe.ddph, TurbineMP.proe.duph, TurbineMP.proe.duhp, TurbineMP.proe.x) = $cse301 26/94 (10): ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_ph(TurbineBP.Te, TurbineBP.proe.d, TurbineBP.proe.u, TurbineBP.proe.s, TurbineBP.proe.cp, TurbineBP.proe.ddhp, TurbineBP.proe.ddph, TurbineBP.proe.duph, TurbineBP.proe.duhp, TurbineBP.proe.x) = $cse304 Variables: 1: TurbineBP.Te:VARIABLE(min = 200.0 max = 6000.0 start = 288.15 unit = "K" nominal = 300.0 ) "Temperature at the inlet" type: Real 2: TurbineBP.proe.duhp:VARIABLE(unit = "1" ) "Derivative of specific inner energy wrt. specific enthalpy at constant pressure" type: Real 3: TurbineBP.proe.u:VARIABLE(min = -1e8 max = 1e8 unit = "J/kg" nominal = 1e6 ) "Specific inner energy" type: Real 4: TurbineBP.proe.cp:VARIABLE(min = 1e-9 max = 1e60 unit = "J/(kg.K)" nominal = 1000.0 ) "Specific heat capacity at constant presure" type: Real 5: TurbineMP.proe.ddph:VARIABLE(unit = "s2/m2" ) "Derivative of density wrt. pressure at constant specific enthalpy" type: Real 6: TurbineMP.proe.cp:VARIABLE(min = 1e-9 max = 1e60 unit = "J/(kg.K)" nominal = 1000.0 ) "Specific heat capacity at constant presure" type: Real 7: TurbineMP.proe.duhp:VARIABLE(unit = "1" ) "Derivative of specific inner energy wrt. specific enthalpy at constant pressure" type: Real 8: TurbineMP.proe.u:VARIABLE(min = -1e8 max = 1e8 unit = "J/kg" nominal = 1e6 ) "Specific inner energy" type: Real 9: TurbineMP.proe.s:VARIABLE(min = -1e6 max = 1e6 unit = "J/(kg.K)" nominal = 1000.0 ) "Specific entropy" type: Real 10: TurbineMP.Te:VARIABLE(min = 200.0 max = 6000.0 start = 288.15 unit = "K" nominal = 300.0 ) "Temperature at the inlet" type: Real 11: TurbineMP.proe.x:VARIABLE(min = 0.0 max = 1.0 unit = "1" ) "Vapor mass fraction" type: Real 12: TurbineMP.proe.d:VARIABLE(min = 1e-9 max = 1e5 unit = "kg/m3" nominal = 998.0 ) "Density" type: Real 13: TurbineMP.proe.ddhp:VARIABLE(unit = "kg.s2/m5" ) "Derivative of density wrt. specific enthalpy at constant pressure" type: Real 14: TurbineMP.proe.duph:VARIABLE(unit = "m3/kg" ) "Derivative of specific inner energy wrt. pressure at constant specific enthalpy" type: Real 15: $cse301.d:VARIABLE(protected = true ) type: Real unreplaceable 16: $cse301.s:VARIABLE(protected = true ) type: Real unreplaceable 17: $cse301.u:VARIABLE(protected = true ) type: Real unreplaceable 18: $cse301.ddph:VARIABLE(protected = true ) type: Real unreplaceable 19: $cse301.cp:VARIABLE(protected = true ) type: Real unreplaceable 20: $cse301.ddhp:VARIABLE(protected = true ) type: Real unreplaceable 21: $cse301.duph:VARIABLE(protected = true ) type: Real unreplaceable 22: $cse301.x:VARIABLE(protected = true ) type: Real unreplaceable 23: $cse301.T:VARIABLE(protected = true ) type: Real unreplaceable 24: $cse301.duhp:VARIABLE(protected = true ) type: Real unreplaceable 25: MelangeurPreTMP.Cs.h:VARIABLE(flow=false start = 1e5 unit = "J/kg" ) "Specific enthalpy of the fluid crossing the boundary of the control volume" type: Real 26: TurbineMP.Q:VARIABLE(start = 500.0 unit = "kg/s" ) "Mass flow rate" type: Real 27: MelangeurPostTMP1.Cs.h:VARIABLE(flow=false start = 1e5 unit = "J/kg" ) "Specific enthalpy of the fluid crossing the boundary of the control volume" type: Real 28: TurbineBP.eta_is:VARIABLE(start = 0.9538 ) "Isentropic efficiency" type: Real 29: $cse311:VARIABLE(protected = true ) type: Real unreplaceable 30: perteChargeK1.Q:VARIABLE(start = 100.0 unit = "kg/s" ) "Mass flow rate" type: Real 31: perteChargeK1.deltaPg:VARIABLE(unit = "Pa" ) "Gravity pressure loss" type: Real 32: perteChargeK1.rho:VARIABLE(min = 0.0 start = 998.0 unit = "kg/m3" ) "Fluid density" type: Real 33: perteChargeK1.deltaPf:VARIABLE(unit = "Pa" ) "Friction pressure loss" type: Real 34: perteChargeK1.deltaP:VARIABLE(unit = "Pa" ) "Total pressure loss" type: Real 35: perteChargeK1.h:VARIABLE(start = 2.4e6 unit = "J/kg" ) "Fluid specific enthalpy" type: Real 36: perteChargeK1.Pm:VARIABLE(min = 0.0 start = 10026.138683139128 unit = "Pa" nominal = 1e5 ) "Average fluid pressure" type: Real 37: TurbineBP.Hrs:VARIABLE(start = 2.40103e6 unit = "J/kg" ) "Fluid specific enthalpy after the real expansion" type: Real 38: TurbineBP.Vs:VARIABLE(unit = "m/s" ) "Fluid velocity at the outlet" type: Real 39: TurbineBP.pros.ddph:VARIABLE(unit = "s2/m2" ) "Derivative of density wrt. pressure at constant specific enthalpy" type: Real 40: TurbineBP.Ts:VARIABLE(min = 200.0 max = 6000.0 start = 288.15 unit = "K" nominal = 300.0 ) "Temperature at the outlet" type: Real 41: TurbineBP.pros.ddhp:VARIABLE(unit = "kg.s2/m5" ) "Derivative of density wrt. specific enthalpy at constant pressure" type: Real 42: TurbineBP.pros.u:VARIABLE(min = -1e8 max = 1e8 unit = "J/kg" nominal = 1e6 ) "Specific inner energy" type: Real 43: TurbineBP.rhos:VARIABLE(min = 1e-9 max = 1e5 start = 200.0 unit = "kg/m3" nominal = 998.0 ) "Fluid density at the outlet" type: Real 44: TurbineBP.pros.duhp:VARIABLE(unit = "1" ) "Derivative of specific inner energy wrt. specific enthalpy at constant pressure" type: Real 45: TurbineBP.pros.x:VARIABLE(min = 0.0 max = 1.0 unit = "1" ) "Vapor mass fraction" type: Real 46: TurbineBP.pros.s:VARIABLE(min = -1e6 max = 1e6 unit = "J/(kg.K)" nominal = 1000.0 ) "Specific entropy" type: Real 47: TurbineBP.pros.cp:VARIABLE(min = 1e-9 max = 1e60 unit = "J/(kg.K)" nominal = 1000.0 ) "Specific heat capacity at constant presure" type: Real 48: TurbineBP.pros.duph:VARIABLE(unit = "m3/kg" ) "Derivative of specific inner energy wrt. pressure at constant specific enthalpy" type: Real 49: $cse305.d:VARIABLE(protected = true ) type: Real unreplaceable 50: $cse305.ddhp:VARIABLE(protected = true ) type: Real unreplaceable 51: $cse305.ddph:VARIABLE(protected = true ) type: Real unreplaceable 52: $cse305.x:VARIABLE(protected = true ) type: Real unreplaceable 53: $cse305.cp:VARIABLE(protected = true ) type: Real unreplaceable 54: $cse305.u:VARIABLE(protected = true ) type: Real unreplaceable 55: $cse305.s:VARIABLE(protected = true ) type: Real unreplaceable 56: $cse305.duph:VARIABLE(protected = true ) type: Real unreplaceable 57: $cse305.T:VARIABLE(protected = true ) type: Real unreplaceable 58: $cse305.duhp:VARIABLE(protected = true ) type: Real unreplaceable 59: TurbineBP.pros1.duhp:VARIABLE(unit = "1" ) "Derivative of specific inner energy wrt. specific enthalpy at constant pressure" type: Real 60: TurbineBP.pros1.duph:VARIABLE(unit = "m3/kg" ) "Derivative of specific inner energy wrt. pressure at constant specific enthalpy" type: Real 61: TurbineBP.pros1.cp:VARIABLE(min = 1e-9 max = 1e60 unit = "J/(kg.K)" nominal = 1000.0 ) "Specific heat capacity at constant presure" type: Real 62: TurbineBP.pros1.u:VARIABLE(min = -1e8 max = 1e8 unit = "J/kg" nominal = 1e6 ) "Specific inner energy" type: Real 63: TurbineBP.pros1.T:VARIABLE(min = 200.0 max = 6000.0 start = 288.15 unit = "K" nominal = 320.0 ) "Temperature" type: Real 64: TurbineBP.pros1.ddhp:VARIABLE(unit = "kg.s2/m5" ) "Derivative of density wrt. specific enthalpy at constant pressure" type: Real 65: TurbineBP.pros1.d:VARIABLE(min = 1e-9 max = 1e5 unit = "kg/m3" nominal = 998.0 ) "Density" type: Real 66: TurbineBP.pros1.s:VARIABLE(min = -1e6 max = 1e6 unit = "J/(kg.K)" nominal = 1000.0 ) "Specific entropy" type: Real 67: TurbineBP.pros1.ddph:VARIABLE(unit = "s2/m2" ) "Derivative of density wrt. pressure at constant specific enthalpy" type: Real 68: TurbineBP.Ps:VARIABLE(min = 0.0 start = 10053.0 unit = "Pa" nominal = 1e5 ) "Pressure at the outlet" type: Real 69: TurbineBP.pros1.x:VARIABLE(min = 0.0 max = 1.0 unit = "1" ) "Vapor mass fraction" type: Real 70: TurbineBP.xm:VARIABLE(min = 0.0 start = 1.0 ) "Average vapor mass fraction" type: Real 71: TurbineBP.props.d:VARIABLE(min = 1e-9 max = 1e5 unit = "kg/m3" nominal = 998.0 ) "Density" type: Real 72: TurbineBP.props.u:VARIABLE(min = -1e8 max = 1e8 unit = "J/kg" nominal = 1e6 ) "Specific inner energy" type: Real 73: TurbineBP.His:VARIABLE(min = -1e6 max = 1e8 unit = "J/kg" nominal = 1e6 ) "Fluid specific enthalpy after isentropic expansion" type: Real 74: TurbineBP.props.ddsp:VARIABLE(unit = "kg2.K/(m3.J)" ) "Derivative of the density wrt. specific entropy at constant pressure" type: Real 75: TurbineBP.props.cp:VARIABLE(min = 1e-9 max = 1e60 unit = "J/(kg.K)" nominal = 1000.0 ) "Specific heat capacity at constant pressure" type: Real 76: TurbineBP.props.ddps:VARIABLE(unit = "s2/m2" ) "Derivative of the density wrt. pressure at constant specific entropy" type: Real 77: TurbineBP.props.x:VARIABLE(min = 0.0 max = 1.0 unit = "1" ) "Vapor mass fraction" type: Real 78: TurbineBP.props.T:VARIABLE(min = 200.0 max = 6000.0 start = 288.15 unit = "K" nominal = 320.0 ) "Temperature" type: Real 79: $cse306.ddsp:VARIABLE(protected = true ) type: Real unreplaceable 80: $cse306.h:VARIABLE(protected = true ) type: Real unreplaceable 81: $cse306.d:VARIABLE(protected = true ) type: Real unreplaceable 82: $cse306.u:VARIABLE(protected = true ) type: Real unreplaceable 83: $cse306.cp:VARIABLE(protected = true ) type: Real unreplaceable 84: $cse306.ddps:VARIABLE(protected = true ) type: Real unreplaceable 85: $cse306.T:VARIABLE(protected = true ) type: Real unreplaceable 86: $cse306.x:VARIABLE(protected = true ) type: Real unreplaceable 87: TurbineBP.proe.s:VARIABLE(min = -1e6 max = 1e6 unit = "J/(kg.K)" nominal = 1000.0 ) "Specific entropy" type: Real 88: TurbineBP.proe.duph:VARIABLE(unit = "m3/kg" ) "Derivative of specific inner energy wrt. pressure at constant specific enthalpy" type: Real 89: TurbineBP.proe.ddhp:VARIABLE(unit = "kg.s2/m5" ) "Derivative of density wrt. specific enthalpy at constant pressure" type: Real 90: TurbineBP.proe.d:VARIABLE(min = 1e-9 max = 1e5 unit = "kg/m3" nominal = 998.0 ) "Density" type: Real 91: TurbineBP.proe.ddph:VARIABLE(unit = "s2/m2" ) "Derivative of density wrt. pressure at constant specific enthalpy" type: Real 92: TurbineBP.proe.x:VARIABLE(min = 0.0 max = 1.0 unit = "1" ) "Vapor mass fraction" type: Real 93: $cse304.duph:VARIABLE(protected = true ) type: Real unreplaceable 94: $cse304.duhp:VARIABLE(protected = true ) type: Real unreplaceable 95: $cse304.s:VARIABLE(protected = true ) type: Real unreplaceable 96: $cse304.ddhp:VARIABLE(protected = true ) type: Real unreplaceable 97: $cse304.T:VARIABLE(protected = true ) type: Real unreplaceable 98: $cse304.x:VARIABLE(protected = true ) type: Real unreplaceable 99: $cse304.ddph:VARIABLE(protected = true ) type: Real unreplaceable 100: $cse304.u:VARIABLE(protected = true ) type: Real unreplaceable 101: $cse304.d:VARIABLE(protected = true ) type: Real unreplaceable 102: $cse304.cp:VARIABLE(protected = true ) type: Real unreplaceable 103: TurbineBP.Pe:VARIABLE(min = 0.0 start = 476799.99999954 unit = "Pa" fixed = true nominal = 1e5 ) "Pressure at the inlet" type: Real [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/BackEnd/BackendDAEUtil.mo:9805:5-9806:77:writable] Error: Internal error BackendDAEUtil.traverseEqSystemStrongComponents failed with function: omc_DAEMode_traverserStrongComponents Notification: Performance of postOpt createDAEmodeBDAE (simulation): time 0.007491/22.57, allocations: 6.499 MB / 6.883 GB, free: 338.2 MB / 1.045 GB Error: post-optimization module createDAEmodeBDAE (simulation) failed. Error: Internal error SimCode DAEmode: The model ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC could not be translated