Environment - simulationEnvironment: startTime=0 stopTime=6 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0024 Regular simulation: ./ThermoPower_ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_D -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/Water.mo:169:5-169:70:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((FluidSink.p0 >= 611.657 and FluidSink.p0 <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= FluidSink.p0 <= 1e8, has value: 0" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/Water.mo:187:5-187:48:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((FluidSink.p >= 611.657 and FluidSink.p <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= FluidSink.p <= 1e8, has value: 0" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0034497s reading init.xml | | | | | | 0.000387226s reading info.xml | | | | | | 0.00017095s [ 0.0%] pre-initialization | | | | | | 0.0185575s [ 5.3%] initialization | | | | | | 9.7112e-05s [ 0.0%] steps | | | | | | 0.0210075s [ 6.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00102993s [ 0.3%] event-handling | | | | | | 0.0110412s [ 3.2%] overhead | | | | | | 0.295674s [ 85.1%] simulation | | | | | | 0.347578s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 79 steps taken | | | | | | 95 calls of functionODE | | | | | | 36 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0158453s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.