Environment - simulationEnvironment: startTime=0 stopTime=5 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.002 Regular simulation: ./ThermoPower_ThermoPower.Test.DistributedParameterComponents.TestWalls -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00117903s reading init.xml | | | | | | 0.000101009s reading info.xml | | | | | | 0.000134863s [ 2.6%] pre-initialization | | | | | | 0.000102181s [ 2.0%] initialization | | | | | | 7.12e-07s [ 0.0%] steps | | | | | | 0.00116733s [ 22.6%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | -7.75565e-21s [ -0.0%] event-handling | | | | | | 0.000463466s [ 9.0%] overhead | | | | | | 0.00318111s [ 61.6%] simulation | | | | | | 0.00516093s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 55 steps taken | | | | | | 70 calls of functionODE | | | | | | 18 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 1.24214e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.