Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0004 Regular simulation: ./PowerSysPro_PowerSysPro.Examples.MediumNetworks.DoubleNetwork -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1-master/package.mo:484:11-484:161:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((tra2.SA <= 2.5e5)) --> ">>> Apparent power flowing the transformer is exceeding the nominal power for DoubleNetwork.tra2" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1-master/package.mo:452:9-452:131:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not load1.U < load1.minU)) --> ">>> Voltage is below the minimum acceptable value for DoubleNetwork.load1" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1-master/package.mo:452:9-452:131:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not load4.U < load4.minU)) --> ">>> Voltage is below the minimum acceptable value for DoubleNetwork.load4" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1-master/package.mo:452:9-452:131:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not load5.U < load5.minU)) --> ">>> Voltage is below the minimum acceptable value for DoubleNetwork.load5" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1-master/package.mo:452:9-452:131:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not load8.U < load8.minU)) --> ">>> Voltage is below the minimum acceptable value for DoubleNetwork.load8" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00428993s reading init.xml | | | | | | 0.000433023s reading info.xml | | | | | | 0.000198923s [ 1.8%] pre-initialization | | | | | | 0.000487264s [ 4.4%] initialization | | | | | | 1.042e-06s [ 0.0%] steps | | | | | | 0.00177053s [ 16.1%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | -3.70577e-22s [ -0.0%] event-handling | | | | | | 0.0030229s [ 27.6%] overhead | | | | | | 0.00541345s [ 49.3%] simulation | | | | | | 0.0109719s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 24 steps taken | | | | | | 24 calls of functionODE | | | | | | 22 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000360378s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.