Environment - simulationEnvironment: startTime=0 stopTime=6 tolerance=1e-06 numberOfIntervals=24000 stepSize=0.00025 Regular simulation: ./Modelica_4.1.0_Modelica.Electrical.Analog.Examples.ControlledSwitchWithArc -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00161218s reading init.xml | | | | | | 0.000109416s reading info.xml | | | | | | 0.000227386s [ 0.6%] pre-initialization | | | | | | 0.000131286s [ 0.3%] initialization | | | | | | 8.92e-07s [ 0.0%] steps | | | | | | 0.00745913s [ 19.8%] solver (excl. callbacks) | | | | | | 0.00324379s [ 8.6%] creating output-file | | | | | | 0.00011232s [ 0.3%] event-handling | | | | | | 0.00272258s [ 7.2%] overhead | | | | | | 0.0237021s [ 63.0%] simulation | | | | | | 0.0375995s [100.0%] total | | | | | events | | | | | | 18 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 2718 steps taken | | | | | | 3712 calls of functionODE | | | | | | 934 evaluations of jacobian | | | | | | 174 error test failures | | | | | | 36 convergence test failures | | | | | | 0.000861865s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.