Environment - simulationEnvironment: startTime=0 stopTime=14 tolerance=1e-05 numberOfIntervals=4666 stepSize=0.00300043 Regular simulation: ./Modelica_3.2.3_Modelica.Magnetic.FluxTubes.Examples.Hysteresis.HysteresisModelComparison -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STDOUT | info | ##IDA## -3 error occurred at time = 0 LOG_STDOUT | info | model terminate | Integrator failed. | Simulation terminated at time 0 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0135044s reading init.xml | | | | | | 0.00140342s reading info.xml | | | | | | 0.00057565s [ 39.3%] pre-initialization | | | | | | 0.000561092s [ 38.3%] initialization | | | | | | 0.000264135s [ 18.0%] steps | | | | | | 0.000735588s [ 50.2%] solver (excl. callbacks) | | | | | | 0.000264868s [ 18.1%] creating output-file | | | | | | 9.51e-07s [ 0.1%] event-handling | | | | | | 4.728e-06s [ 0.3%] overhead | | | | | | -0.000943026s [-64.4%] simulation | | | | | | 0.00146399s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 0 steps taken | | | | | | 20 calls of functionODE | | | | | | 10 evaluations of jacobian | | | | | | 10 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00016495s time of jacobian evaluation