Environment - simulationEnvironment: startTime=0 stopTime=200 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.08 Regular simulation: ./IBPSA_latest_IBPSA.Obsolete.Fluid.Movers.Validation.PowerEuler -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump_dp.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in PowerEuler.pump_dp: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:419:3-429:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in PowerEuler.pump_dp: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump_m_flow.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in PowerEuler.pump_m_flow: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:419:3-429:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in PowerEuler.pump_m_flow: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | debug | ##IDA## In function IDAGetNumNonlinSolvIters: The linear solver's setup function failed in an unrecoverable manner. LOG_ASSERT | info | simulation terminated by an assertion at initialization