Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_dev_Dynawo.Examples.SMIB.Standard.GovSteam1St4b2.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 90] Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001302/0.001302, allocations: 105.2 kB / 18.05 MB, free: 4.32 MB / 14.72 MB [Timeout remaining time 90] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 90] Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001339/0.001339, allocations: 186 kB / 21.17 MB, free: 1.211 MB / 14.72 MB [Timeout remaining time 90] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 90] Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.439/1.439, allocations: 207.6 MB / 231.7 MB, free: 3.223 MB / 174.1 MB [Timeout remaining time 88] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/package.mo", uses=false) [Timeout 90] Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/package.mo): time 0.5754/0.5754, allocations: 101.8 MB / 385.6 MB, free: 15.49 MB / 318.1 MB [Timeout remaining time 89] Using package Dynawo with version 1.7.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Ignoring simflag -noemit -emit_protected=() since it seems broken on HelloWorld Running command: translateModel(Dynawo.Examples.SMIB.Standard.GovSteam1St4b2,tolerance=1e-06,outputFormat="empty",numberOfIntervals=500,variableFilter="",fileNamePrefix="Dynawo_dev_Dynawo.Examples.SMIB.Standard.GovSteam1St4b2") translateModel(Dynawo.Examples.SMIB.Standard.GovSteam1St4b2,tolerance=1e-06,outputFormat="empty",numberOfIntervals=500,variableFilter="",fileNamePrefix="Dynawo_dev_Dynawo.Examples.SMIB.Standard.GovSteam1St4b2") [Timeout 660] Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002172/0.002172, allocations: 71.89 kB / 0.5448 GB, free: 14.52 MB / 414.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1468/0.149, allocations: 75.37 MB / 0.6184 GB, free: 3.055 MB / 478.1 MB Notification: Performance of NFInst.instantiate(Dynawo.Examples.SMIB.Standard.GovSteam1St4b2): time 0.01101/0.16, allocations: 8.439 MB / 0.6267 GB, free: 10.57 MB / 494.1 MB Notification: Performance of NFInst.instExpressions: time 0.007888/0.1679, allocations: 4.604 MB / 0.6312 GB, free: 5.945 MB / 494.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.0009619/0.1689, allocations: 35.81 kB / 0.6312 GB, free: 5.91 MB / 494.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:24:3-24:104:writable] Warning: Connector omegaRefPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:25:3-25:94:writable] Warning: Connector PmPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:26:3-26:125:writable] Warning: Connector efdPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:29:3-29:96:writable] Warning: Connector omegaPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:42:3-42:108:writable] Warning: Connector UStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:43:3-43:115:writable] Warning: Connector IStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:44:3-44:116:writable] Warning: Connector QStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:45:3-45:126:writable] Warning: Connector QStatorPuQNom is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:46:3-46:123:writable] Warning: Connector IRotorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:47:3-47:95:writable] Warning: Connector thetaInternal is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.001109/0.17, allocations: 392.3 kB / 0.6316 GB, free: 5.527 MB / 494.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Utilities/Strings.mo:139:3-175:14:writable] Warning: Pure function 'Modelica.Utilities.Strings.isEmpty' contains a call to impure function 'Modelica.Utilities.Strings.Advanced.skipWhiteSpace'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Machines/VoltageRegulators/Standard/BaseClasses/RectifierRegulationCharacteristic.mo:22:3-22:139:writable] Warning: In relation avr.rectifierRegulationCharacteristic.ULow == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Machines/VoltageRegulators/Standard/BaseClasses/RectifierRegulationCharacteristic.mo:23:3-23:131:writable] Warning: In relation avr.rectifierRegulationCharacteristic.UHigh == 1.0, == on Real numbers is only allowed inside functions. Notification: Performance of NFTyping.typeBindings: time 0.001385/0.1714, allocations: 0.5237 MB / 0.6321 GB, free: 5 MB / 494.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/SMIB/Standard/GovSteam1St4b2.mo:146:3-146:54:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/SMIB/Standard/GovSteam1St4b2.mo:147:3-147:54:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/SMIB/Standard/GovSteam1St4b2.mo:149:3-149:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:133:3-133:117:writable] Warning: In relation generatorSynchronous.SNom <> generatorSynchronous.PNomAlt, <> on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. Notification: Performance of NFTyping.typeClassSections: time 0.003656/0.175, allocations: 1.778 MB / 0.6338 GB, free: 3.227 MB / 494.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:51:3-51:114:writable] Error: Parameter generatorSynchronous.MdPPuEfd has neither value nor start value, and is fixed during initialization (fixed=true). Notification: Performance of FrontEnd: time 0.0002064/0.1752, allocations: 115.4 kB / 0.6339 GB, free: 3.113 MB / 494.1 MB [Timeout remaining time 660]