startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 Regular simulation: ./Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2 -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2: Using pre-compiled FMU /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Resources/src/ThermalZones/EnergyPlus/FMUs/Zones3.fmu stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2: Warning: Variable South_ZN_mSenFac does not specify units in /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2/EnergyPlus-simulation-Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2/Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2.fmu. It will not be converted to SI units. stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2: Warning: Variable Core_ZN_mSenFac does not specify units in /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2/EnergyPlus-simulation-Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2/Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2.fmu. It will not be converted to SI units. stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2: Warning from EnergyPlus: "*** Test warning written by Zones3.core.&##10;" stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2: Warning from EnergyPlus: "*** Test warning written by Zones3.north.&##10;" stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2: Warning from EnergyPlus: "*** Test warning written by Zones3.south.&##10;" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00130986s reading init.xml | | | | | | 0.000123932s reading info.xml | | | | | | 0.00010622s [ 0.5%] pre-initialization | | | | | | 0.00884208s [ 45.4%] initialization | | | | | | 6.11e-07s [ 0.0%] steps | | | | | | 0.0112882s [ 58.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00373062s [ 19.2%] event-handling | | | | | | 0.00112088s [ 5.8%] overhead | | | | | | -0.0056289s [-28.9%] simulation | | | | | | 0.0194597s [100.0%] total | | | | | events | | | | | | 59 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 1100 steps taken | | | | | | 1100 calls of functionODE | | | | | | 980 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00038093s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.