startTime=0 stopTime=600 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.24 Regular simulation: ./Buildings_maint.8.0.x_Buildings.Fluid.Sources.Examples.TraceSubstancesFlowSource -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not C.warnAboutOnePortConnection assert | warning | Sensor Buildings.Fluid.Sources.Examples.TraceSubstancesFlowSource.C can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'Buildings.Fluid.MixingVolumes`. | | | | See Buildings.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in Buildings.Fluid.Sources.Examples.TraceSubstancesFlowSource.C. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not C1.warnAboutOnePortConnection assert | warning | Sensor Buildings.Fluid.Sources.Examples.TraceSubstancesFlowSource.C1 can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'Buildings.Fluid.MixingVolumes`. | | | | See Buildings.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in Buildings.Fluid.Sources.Examples.TraceSubstancesFlowSource.C1. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not C2.warnAboutOnePortConnection assert | warning | Sensor Buildings.Fluid.Sources.Examples.TraceSubstancesFlowSource.C2 can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'Buildings.Fluid.MixingVolumes`. | | | | See Buildings.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in Buildings.Fluid.Sources.Examples.TraceSubstancesFlowSource.C2. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not C3.warnAboutOnePortConnection assert | warning | Sensor Buildings.Fluid.Sources.Examples.TraceSubstancesFlowSource.C3 can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'Buildings.Fluid.MixingVolumes`. | | | | See Buildings.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in Buildings.Fluid.Sources.Examples.TraceSubstancesFlowSource.C3. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0139271s reading init.xml | | | | | | 0.00142384s reading info.xml | | | | | | 0.000281378s [ 1.0%] pre-initialization | | | | | | 0.000452429s [ 1.6%] initialization | | | | | | 1.683e-06s [ 0.0%] steps | | | | | | 0.00588055s [ 20.8%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0s [ 0.0%] event-handling | | | | | | 0.0108112s [ 38.3%] overhead | | | | | | 0.0107777s [ 38.2%] simulation | | | | | | 0.0282224s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 751 steps taken | | | | | | 1211 calls of functionODE | | | | | | 121 evaluations of jacobian | | | | | | 40 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00103959s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.