startTime=0 stopTime=10000 tolerance=1e-06 numberOfIntervals=2500 stepSize=4 Regular simulation: ./Buildings_maint.8.0.x_Buildings.Fluid.CHPs.Validation.ElectricalFollowing -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Resources/Data/Fluid/CHPs/Validation/MicroCogeneration.mos" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0166336s reading init.xml | | | | | | 0.00159409s reading info.xml | | | | | | 0.000232105s [ 0.5%] pre-initialization | | | | | | 0.00287251s [ 6.4%] initialization | | | | | | 5.911e-06s [ 0.0%] steps | | | | | | 0.0129965s [ 28.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00165998s [ 3.7%] event-handling | | | | | | 0.00527432s [ 11.7%] overhead | | | | | | 0.0219765s [ 48.8%] simulation | | | | | | 0.0450178s [100.0%] total | | | | | events | | | | | | 19 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 2810 steps taken | | | | | | 4595 calls of functionODE | | | | | | 960 evaluations of jacobian | | | | | | 324 error test failures | | | | | | 6 convergence test failures | | | | | | 0.00495391s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.