startTime=0 stopTime=142 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0568 Regular simulation: ./Buildings_maint.7.0.x_Buildings.Fluid.HeatPumps.Calibration.ScrollWaterToWater -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | ... loading "ManufacturerData" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Resources/src/fluid/heatpumps/calibration/manufacturerData.txt" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00762067s reading init.xml | | | | | | 0.000721493s reading info.xml | | | | | | 0.000151123s [ 0.1%] pre-initialization | | | | | | 0.0011452s [ 0.7%] initialization | | | | | | 1.322e-06s [ 0.0%] steps | | | | | | 0.0373261s [ 23.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.051307s [ 31.6%] event-handling | | | | | | 0.0085251s [ 5.2%] overhead | | | | | | 0.0639445s [ 39.4%] simulation | | | | | | 0.1624s [100.0%] total | | | | | events | | | | | | 141 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 2560 steps taken | | | | | | 2595 calls of functionODE | | | | | | 2276 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0885445s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.