Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_latest_Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SingleFamilyHouse.AirHeating -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.04.30 18:40 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (fan.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or fan.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in AirHeating.fan: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((fan.per.haveWMot_nominal or not (fan.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or fan.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in AirHeating.fan: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STDOUT | info | ##IDA## -4 error occurred at time = 5353.58061157644 LOG_STDOUT | info | model terminate | Integrator failed. | Simulation terminated at time 5353.58 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0151479s reading init.xml | | | | | | 0.00161762s reading info.xml | | | | | | 0.000718177s [ 0.0%] pre-initialization | | | | | | 7.90554s [ 99.9%] initialization | | | | | | 0.000148829s [ 0.0%] steps | | | | | | 7.90768s [ 99.9%] solver (excl. callbacks) | | | | | | 0.000558635s [ 0.0%] creating output-file | | | | | | 0.00414225s [ 0.1%] event-handling | | | | | | 0.00108946s [ 0.0%] overhead | | | | | | -7.9027s [-99.8%] simulation | | | | | | 7.91718s [100.0%] total | | | | | events | | | | | | 12 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 653 steps taken | | | | | | 878 calls of functionODE | | | | | | 226 evaluations of jacobian | | | | | | 19 error test failures | | | | | | 13 convergence test failures | | | | | | 0.00239084s time of jacobian evaluation Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.31sec EnergyPlus Completed Successfully.