Environment - simulationEnvironment:
startTime=0
stopTime=3600
tolerance=1e-06
numberOfIntervals=2500
stepSize=1.44
Regular simulation: ./Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones2 -abortSlowSimulation -alarm=800 -lv LOG_STATS
LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used.
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Using pre-compiled FMU /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Resources/src/ThermalZones/EnergyPlus/FMUs/Zones3.fmu
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Warning: Variable South_ZN_mSenFac does not specify units in /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones2/spawn-FMUZoneAdapterZones2/EnergyPlus.fmu. It will not be converted to SI units.
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Warning: Variable Core_ZN_mSenFac does not specify units in /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones2/spawn-FMUZoneAdapterZones2/EnergyPlus.fmu. It will not be converted to SI units.
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Warning from EnergyPlus: "*** Test warning written by Zones3.core.#10;"
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Warning from EnergyPlus: "*** Test warning written by Zones3.north.#10;"
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Warning from EnergyPlus: "*** Test warning written by Zones3.south.#10;"
LOG_SUCCESS | info | The initialization finished successfully without homotopy method.
LOG_STATS | info | ### STATISTICS ###
| | | | | timer
| | | | | | 0.00510257s reading init.xml
| | | | | | 0.00050114s reading info.xml
| | | | | | 0.000190427s [ 0.2%] pre-initialization
| | | | | | 0.0703771s [ 81.5%] initialization
| | | | | | 2.315e-06s [ 0.0%] steps
| | | | | | 0.0732319s [ 84.9%] solver (excl. callbacks)
| | | | | | 0s [ 0.0%] creating output-file
| | | | | | 0.00491297s [ 5.7%] event-handling
| | | | | | 0.00261035s [ 3.0%] overhead
| | | | | | -0.0650186s [-75.3%] simulation
| | | | | | 0.0863065s [100.0%] total
| | | | | events
| | | | | | 59 state events
| | | | | | 0 time events
| | | | | solver: ida
| | | | | | 1040 steps taken
| | | | | | 1040 calls of functionODE
| | | | | | 920 evaluations of jacobian
| | | | | | 0 error test failures
| | | | | | 0 convergence test failures
| | | | | | 0.000978513s time of jacobian evaluation
LOG_SUCCESS | info | The simulation finished successfully.