Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WaterHeater_T -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (mov.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or mov.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in WaterHeater_T.mov: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((mov.per.haveWMot_nominal or not (mov.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or mov.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in WaterHeater_T.mov: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STDOUT | info | ##IDA## -4 error occurred at time = 22247.1792964262 LOG_STDOUT | info | model terminate | Integrator failed. | Simulation terminated at time 22247.2 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00910747s reading init.xml | | | | | | 0.000822954s reading info.xml | | | | | | 0.000496041s [ 11.7%] pre-initialization | | | | | | 0.000306655s [ 7.2%] initialization | | | | | | 7.0603e-05s [ 1.7%] steps | | | | | | 0.00104818s [ 24.7%] solver (excl. callbacks) | | | | | | 0.000439927s [ 10.4%] creating output-file | | | | | | -2.0117e-21s [ -0.0%] event-handling | | | | | | 0.000913975s [ 21.6%] overhead | | | | | | 0.000942619s [ 22.2%] simulation | | | | | | 0.00424158s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 284 steps taken | | | | | | 463 calls of functionODE | | | | | | 100 evaluations of jacobian | | | | | | 27 error test failures | | | | | | 13 convergence test failures | | | | | | 0.000309002s time of jacobian evaluation