Environment - simulationEnvironment: startTime=0 stopTime=186360 tolerance=1e-06 numberOfIntervals=2500 stepSize=74.544 Regular simulation: ./Buildings_latest_Buildings.Fluid.Geothermal.Borefields.Validation.Sandbox -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_STDOUT | info | ... loading "data" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Resources/Data/Fluid/Geothermal/Borefields/HeatTransfer/Validation/Beier_Smith_Spitler_2011_SandBox.txt" LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/1d2f5fcf3b3ff954b7c65c809e2f939106c2fa87TStep.mat" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in Sandbox.pum: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pum.per.haveWMot_nominal or not (pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in Sandbox.pum: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0834226s reading init.xml | | | | | | 0.0077705s reading info.xml | | | | | | 0.00269934s [ 0.0%] pre-initialization | | | | | | 0.570844s [ 6.3%] initialization | | | | | | 0.000675096s [ 0.0%] steps | | | | | | 5.86098s [ 64.6%] solver (excl. callbacks) | | | | | | 0.0356583s [ 0.4%] creating output-file | | | | | | 4.31363s [ 47.5%] event-handling | | | | | | 0.0899363s [ 1.0%] overhead | | | | | | -1.79772s [-19.8%] simulation | | | | | | 9.07671s [100.0%] total | | | | | events | | | | | | 2830 state events | | | | | | 3107 time events | | | | | solver: ida | | | | | | 77173 steps taken | | | | | | 95485 calls of functionODE | | | | | | 27234 evaluations of jacobian | | | | | | 602 error test failures | | | | | | 0 convergence test failures | | | | | | 5.42493s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.