Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_latest_Buildings.DHC.ETS.Cooling.Examples.Direct -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in Direct.pum: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pum.per.haveWMot_nominal or not (pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in Direct.pum: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STDOUT | info | ##IDA## -4 error occurred at time = 43444.1704844803 LOG_STDOUT | info | model terminate | Integrator failed. | Simulation terminated at time 43444.2 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0190771s reading init.xml | | | | | | 0.00181128s reading info.xml | | | | | | 0.00133179s [ 6.2%] pre-initialization | | | | | | 0.000897013s [ 4.2%] initialization | | | | | | 0.000144651s [ 0.7%] steps | | | | | | 0.00495636s [ 22.9%] solver (excl. callbacks) | | | | | | 0.00159402s [ 7.4%] creating output-file | | | | | | 0.000319724s [ 1.5%] event-handling | | | | | | 0.00595619s [ 27.6%] overhead | | | | | | 0.00639824s [ 29.6%] simulation | | | | | | 0.021598s [100.0%] total | | | | | events | | | | | | 3 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 1108 steps taken | | | | | | 1684 calls of functionODE | | | | | | 159 evaluations of jacobian | | | | | | 48 error test failures | | | | | | 11 convergence test failures | | | | | | 0.00127863s time of jacobian evaluation