Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./Buildings_latest_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.ElectricHeater -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (mov.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or mov.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ElectricHeater.mov: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((mov.per.haveWMot_nominal or not (mov.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or mov.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ElectricHeater.mov: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.010414s reading init.xml | | | | | | 0.000942969s reading info.xml | | | | | | 0.000445125s [ 1.6%] pre-initialization | | | | | | 0.000401162s [ 1.4%] initialization | | | | | | 1.323e-06s [ 0.0%] steps | | | | | | 0.00620735s [ 22.1%] solver (excl. callbacks) | | | | | | 0.00142081s [ 5.1%] creating output-file | | | | | | 0.000171598s [ 0.6%] event-handling | | | | | | 0.00893691s [ 31.9%] overhead | | | | | | 0.0104488s [ 37.3%] simulation | | | | | | 0.0280331s [100.0%] total | | | | | events | | | | | | 6 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 2074 steps taken | | | | | | 3198 calls of functionODE | | | | | | 568 evaluations of jacobian | | | | | | 224 error test failures | | | | | | 4 convergence test failures | | | | | | 0.00232281s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.