Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_8_Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.NoOutputVariable -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. EnergyPlus Starting EnergyPlus, Version 9.5.0-e579c2aa82 (No OpenGL), YMD=2024.03.12 05:39 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD LOG_STDOUT | info | 0.000 NoOutputVariable.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-LIVING ZONE-RADIANTGAINS", Activity Level Schedule Name values LOG_STDOUT | info | 0.000 NoOutputVariable.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. LOG_STDOUT | info | 0.000 NoOutputVariable.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". LOG_STDOUT | info | 0.000 NoOutputVariable.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STDOUT | info | 3600.000 NoOutputVariable.building: Warning from EnergyPlus: Calculated Relative Humidity out of range (PsyRhFnTdbWPb) LOG_STDOUT | info | 3600.000 NoOutputVariable.building: Warning from EnergyPlus: Routine=Unknown, Environment=SPAWN-RUNPERIOD, at Simulation time=01/01 00:50 - 00:50 LOG_STDOUT | info | 3600.000 NoOutputVariable.building: Warning from EnergyPlus: Dry-Bulb= -8.30 Humidity Ratio= 2.083E-003 Calculated Relative Humidity [%]= 110.02 LOG_STDOUT | info | 3600.000 NoOutputVariable.building: Warning from EnergyPlus: Relative Humidity being reset to 100.0% LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00619513s reading init.xml | | | | | | 0.000488767s reading info.xml | | | | | | 0.000177332s [ 0.0%] pre-initialization | | | | | | 0.930929s [ 90.8%] initialization | | | | | | 2.595e-06s [ 0.0%] steps | | | | | | 0.945669s [ 92.3%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0515404s [ 5.0%] event-handling | | | | | | 0.00852712s [ 0.8%] overhead | | | | | | -0.911738s [-88.9%] simulation | | | | | | 1.02511s [100.0%] total | | | | | events | | | | | | 143 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 3319 steps taken | | | | | | 4265 calls of functionODE | | | | | | 1911 evaluations of jacobian | | | | | | 9 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0116344s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.40sec EnergyPlus Completed Successfully. LOG_STDOUT | info | 85800.000 NoOutputVariable.building: Warning from EnergyPlus: ** Warning ** Calculated Relative Humidity out of range (PsyRhFnTdbWPb) LOG_STDOUT | info | 85800.000 NoOutputVariable.building: Warning from EnergyPlus: