Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_8_Buildings.ThermalZones.EnergyPlus.Validation.MultipleBuildings.ThreeZonesTwoBuildings -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_STDOUT | info | ... loading "EnergyPlus" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Resources/Data/ThermalZones/EnergyPlus/Validation/TwoIdenticalZones/TwoIdenticalZones.dat" EnergyPlus Starting EnergyPlus, Version 9.5.0-e579c2aa82 (No OpenGL), YMD=2024.03.12 05:39 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD LOG_STDOUT | info | 0.000 ThreeZonesTwoBuildings.zon1.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-LIVING ZONE-RADIANTGAINS", Activity Level Schedule Name values LOG_STDOUT | info | 0.000 ThreeZonesTwoBuildings.zon1.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. LOG_STDOUT | info | 0.000 ThreeZonesTwoBuildings.zon1.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". LOG_STDOUT | info | 0.000 ThreeZonesTwoBuildings.zon1.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 EnergyPlus Starting EnergyPlus, Version 9.5.0-e579c2aa82 (No OpenGL), YMD=2024.03.12 05:39 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD LOG_STDOUT | info | 0.000 ThreeZonesTwoBuildings.zon2.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-THERMAL ZONE 1-RADIANTGAINS", Activity Level Schedule Name values LOG_STDOUT | info | 0.000 ThreeZonesTwoBuildings.zon2.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. LOG_STDOUT | info | 0.000 ThreeZonesTwoBuildings.zon2.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". LOG_STDOUT | info | 0.000 ThreeZonesTwoBuildings.zon2.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 LOG_STDOUT | info | 0.000 ThreeZonesTwoBuildings.zon2.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-THERMAL ZONE 2-RADIANTGAINS", Activity Level Schedule Name values LOG_STDOUT | info | 0.000 ThreeZonesTwoBuildings.zon2.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. LOG_STDOUT | info | 0.000 ThreeZonesTwoBuildings.zon2.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". LOG_STDOUT | info | 0.000 ThreeZonesTwoBuildings.zon2.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 LOG_STDOUT | info | Output ThreeZonesTwoBuildings.zon2.inf1.y has in Modelica the unit 1. LOG_ASSERT | debug | ##IDA## In function IDAGetNumNonlinSolvIters: Convergence test failures occurred too many times during one internal time step or minimum step size was reached. LOG_ASSERT | info | simulation terminated by an assertion at initialization Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 1.62sec EnergyPlus Completed Successfully. Writing tabular output file results using HTML format. Writing final SQL reports EnergyPlus Run Time=00hr 00min 0.77sec EnergyPlus Completed Successfully. LOG_STDOUT | info | 0.000 ThreeZonesTwoBuildings.zon2.building: Warning from EnergyPlus: The following schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 0.000 ThreeZonesTwoBuildings.zon2.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. LOG_STDOUT | info | 0.000 ThreeZonesTwoBuildings.zon2.building: Warning from EnergyPlus: The following week schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 0.000 ThreeZonesTwoBuildings.zon2.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. LOG_STDOUT | info | 0.000 ThreeZonesTwoBuildings.zon2.building: Warning from EnergyPlus: The following day schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 0.000 ThreeZonesTwoBuildings.zon2.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used.