Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case630.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case630,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case630") translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case630,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case630") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 1.614/1.614, allocations: 287.4 MB / 303.2 MB, free: 8.332 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.0009204/0.0009204, allocations: 170.4 kB / 371.8 MB, free: 10.85 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.282/1.282, allocations: 205.4 MB / 0.6304 GB, free: 10.6 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008367/0.0008368, allocations: 95.3 kB / 0.7438 GB, free: 6.578 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004317/0.0004318, allocations: 11.55 kB / 0.8667 GB, free: 140.7 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1768/0.1772, allocations: 115.3 MB / 0.9793 GB, free: 28.21 MB / 0.6198 GB Notification: Performance of NFInst.instantiate(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case630): time 0.5713/0.7486, allocations: 207.4 MB / 1.182 GB, free: 2.629 MB / 0.7136 GB Notification: Performance of NFInst.instExpressions: time 0.05566/0.8043, allocations: 35.61 MB / 1.217 GB, free: 5.621 MB / 0.7448 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01247/0.8168, allocations: 253.6 kB / 1.217 GB, free: 5.52 MB / 0.7448 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case620.mo:9:7-9:36:writable] Error: Component glaSys of variability parameter has binding '{window600, window600}[]' of higher variability continuous. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/HeatTransfer/Data/GlazingSystems.mo:9:5-11:33:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Math/BooleanVectors.mo:59:6-59:30:writable] Warning: Parameter roo.datConExtWin[2].glaSys.haveExteriorShade(fixed = true) has annotation(Evaluate=true) and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case620.mo:9:7-9:36:writable] Error: Component glaSys of variability parameter has binding '{window600, window600}[]' of higher variability continuous. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/HeatTransfer/Data/GlazingSystems.mo:9:5-11:33:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Math/BooleanVectors.mo:59:6-59:30:writable] Warning: Parameter roo.datConExtWin[2].glaSys.haveExteriorShade(fixed = true) has annotation(Evaluate=true) and no binding. [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFCeval.mo:1476:9-1476:67:writable] Error: Internal error NFCeval.evalLogicBinaryOr failed to evaluate ‘roo.datConExtWin[2].glaSys.haveExteriorShade or {roo.datConExtWin[2].glaSys.haveExteriorShade, roo.datConExtWin[2].glaSys.haveExteriorShade}[2]‘