startTime=0 stopTime=1200 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.48 Regular simulation: ./Buildings_7.0.0_Buildings.Fluid.Interfaces.Examples.PrescribedOutlet_X_wSetOnly -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0117197s reading init.xml | | | | | | 0.00120379s reading info.xml | | | | | | 0.000239684s [ 0.5%] pre-initialization | | | | | | 0.000289738s [ 0.6%] initialization | | | | | | 5.401e-06s [ 0.0%] steps | | | | | | 0.004158s [ 8.5%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000120386s [ 0.2%] event-handling | | | | | | 0.0115418s [ 23.7%] overhead | | | | | | 0.032422s [ 66.5%] simulation | | | | | | 0.048777s [100.0%] total | | | | | events | | | | | | 5 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 252 steps taken | | | | | | 318 calls of functionODE | | | | | | 114 evaluations of jacobian | | | | | | 5 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000310454s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.