Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_12_Buildings.Templates.Components.Validation.Pumps.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001694/0.001694, allocations: 109.1 kB / 19.71 MB, free: 2.145 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.002082/0.002082, allocations: 214.4 kB / 23 MB, free: 4.969 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.446/1.446, allocations: 230.6 MB / 256.8 MB, free: 7.816 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo): time 3.14/3.14, allocations: 0.49 GB / 0.7959 GB, free: 35.59 MB / 0.6231 GB " [Timeout remaining time 177] Using package Buildings with version 12.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(Buildings.Templates.Components.Validation.Pumps,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|pum1.bus.y1|pum2.bus.y1|pum1.m_flow|pum2.m_flow|datPum.m_flow_nominal|res.m_flow|res.m_flow_nominal|pumMul.bus.y1.1.|pumMul.bus.y1.2.|pumMul.pum.1..m_flow|pumMul.pum.2..m_flow|pumMul.m_flow_nominal.1.|pumMul.m_flow_nominal.2.|resMul.m_flow|resMul.m_flow_nominal|pumMulCst.bus.y1.1.|pumMulCst.bus.y1.2.|pumMulCst.pum.1..m_flow|pumMulCst.pum.2..m_flow|pumMulCst.m_flow_nominal.1.|pumMulCst.m_flow_nominal.2.|resMulCst.m_flow|resMulCst.m_flow_nominal|pumMulDed.bus.y1.1.|pumMulDed.bus.y1.2.|pumMulDed.pum.1..m_flow|pumMulDed.pum.2..m_flow|pumMulDed.m_flow_nominal.1.|pumMulDed.m_flow_nominal.2.|resMulDed.m_flow|resMulDed.m_flow_nominal",fileNamePrefix="Buildings_12_Buildings.Templates.Components.Validation.Pumps") translateModel(Buildings.Templates.Components.Validation.Pumps,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|pum1.bus.y1|pum2.bus.y1|pum1.m_flow|pum2.m_flow|datPum.m_flow_nominal|res.m_flow|res.m_flow_nominal|pumMul.bus.y1.1.|pumMul.bus.y1.2.|pumMul.pum.1..m_flow|pumMul.pum.2..m_flow|pumMul.m_flow_nominal.1.|pumMul.m_flow_nominal.2.|resMul.m_flow|resMul.m_flow_nominal|pumMulCst.bus.y1.1.|pumMulCst.bus.y1.2.|pumMulCst.pum.1..m_flow|pumMulCst.pum.2..m_flow|pumMulCst.m_flow_nominal.1.|pumMulCst.m_flow_nominal.2.|resMulCst.m_flow|resMulCst.m_flow_nominal|pumMulDed.bus.y1.1.|pumMulDed.bus.y1.2.|pumMulDed.pum.1..m_flow|pumMulDed.pum.2..m_flow|pumMulDed.m_flow_nominal.1.|pumMulDed.m_flow_nominal.2.|resMulDed.m_flow|resMulDed.m_flow_nominal",fileNamePrefix="Buildings_12_Buildings.Templates.Components.Validation.Pumps") [Timeout 300] "Notification: Buildings requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.001955/0.001955, allocations: 67.23 kB / 1.155 GB, free: 25.22 MB / 0.9044 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3136/0.3156, allocations: 176.1 MB / 1.327 GB, free: 0.9922 MB / 1.014 GB Notification: Performance of NFInst.instantiate(Buildings.Templates.Components.Validation.Pumps): time 1.099/1.415, allocations: 406.5 MB / 1.724 GB, free: 51.88 MB / 1.295 GB Notification: Performance of NFInst.instExpressions: time 0.1054/1.52, allocations: 91 MB / 1.813 GB, free: 4.234 MB / 1.295 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01707/1.537, allocations: 0.7276 MB / 1.814 GB, free: 3.852 MB / 1.295 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/Characteristics/flowParameters.mo:5:3-6:57:writable] Error: Dimension 1 of 'V_flow' could not be deduced from the component's binding equation 'datPumMul.per.pressure.V_flow'. Notification: Performance of FrontEnd: time 0.003233/1.541, allocations: 1.285 MB / 1.815 GB, free: 3.125 MB / 1.295 GB " [Timeout remaining time 298] [Calling sys.exit(0), Time elapsed: 7.742815609999525] Failed to read output from testmodel.py, exit status != 0: 1.5470845760064549 1.559565568 -1.0 Calling exit ...