Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./BuildSysPro_BuildSysPro.IBPSA.Fluid.HeatExchangers.Examples.AirHeater_u -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420:3-427:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (mov.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or mov.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in AirHeater_u.mov: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-438:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((mov.per.haveWMot_nominal or not (mov.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or mov.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in AirHeater_u.mov: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0110341s reading init.xml | | | | | | 0.000982744s reading info.xml | | | | | | 0.000162545s [ 0.6%] pre-initialization | | | | | | 0.00033626s [ 1.2%] initialization | | | | | | 1.332e-06s [ 0.0%] steps | | | | | | 0.00630618s [ 22.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000188262s [ 0.7%] event-handling | | | | | | 0.00987336s [ 35.9%] overhead | | | | | | 0.0106144s [ 38.6%] simulation | | | | | | 0.0274824s [100.0%] total | | | | | events | | | | | | 5 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 1970 steps taken | | | | | | 2772 calls of functionODE | | | | | | 312 evaluations of jacobian | | | | | | 126 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00193745s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.