Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr TransiEnt_TransiEnt.Grid.Electrical.EconomicDispatch.Check.TestDiscretizePrediction.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/package.mo): time 3.1/3.1, allocations: 0.5108 GB / 0.5337 GB, free: 12.03 MB / 430.1 MB " [Timeout remaining time 176] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo): time 0.001119/0.001119, allocations: 27.22 kB / 0.6622 GB, free: 14.62 MB / 0.5137 GB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SMArtInt main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SMArtInt main/package.mo): time 0.01216/0.01216, allocations: 1.758 MB / 0.7925 GB, free: 9.152 MB / 0.6387 GB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa main/package.mo): time 0.7677/0.7677, allocations: 130.7 MB / 1.049 GB, free: 59.54 MB / 0.6856 GB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo): time 0.01198/0.01198, allocations: 0.8874 MB / 1.206 GB, free: 61.62 MB / 0.6857 GB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo): time 0.3339/0.3339, allocations: 45.31 MB / 1.407 GB, free: 1.359 MB / 0.8263 GB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.1/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.1/package.mo): time 0.1002/0.1002, allocations: 13.78 MB / 1.586 GB, free: 159.9 MB / 0.8419 GB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001466/0.001466, allocations: 107.5 kB / 1.755 GB, free: 143 MB / 0.8419 GB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001564/0.001564, allocations: 200.5 kB / 1.924 GB, free: 4.965 MB / 0.8419 GB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.977/1.977, allocations: 230.6 MB / 2.318 GB, free: 166.5 MB / 1.045 GB " [Timeout remaining time 177] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo): time 0.0008882/0.0008882, allocations: 35.88 kB / 2.539 GB, free: 4.781 MB / 1.108 GB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo): time 0.000787/0.000787, allocations: 31.56 kB / 2.76 GB, free: 205.1 MB / 1.108 GB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt master/package.mo): time 1.246/1.246, allocations: 223.4 MB / 3.199 GB, free: 10.12 MB / 1.108 GB " [Timeout remaining time 178] Using package TransiEnt with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt master/package.mo) Using package DataFiles with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo) Using package Design with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Using package Modelica_StateGraph2 with version 2.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.1/package.mo) Using package Modelica_LinearSystems2 with version 2.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo) Using package ModelicaReference with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo) Using package ClaRa with version 1.9.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa main/package.mo) Using package SMArtInt with version 0.3.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SMArtInt main/package.mo) Using package DymolaCommands with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo) Using package Buildings with version 13.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/package.mo) Running command: translateModel(TransiEnt.Grid.Electrical.EconomicDispatch.Check.TestDiscretizePrediction,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1440,variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Grid.Electrical.EconomicDispatch.Check.TestDiscretizePrediction") translateModel(TransiEnt.Grid.Electrical.EconomicDispatch.Check.TestDiscretizePrediction,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1440,variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Grid.Electrical.EconomicDispatch.Check.TestDiscretizePrediction") [Timeout 660] "Notification: Performance of FrontEnd - Absyn->SCode: time 2.848e-05/2.848e-05, allocations: 2.281 kB / 3.756 GB, free: 10.13 MB / 1.373 GB Notification: TILMedia requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Automatically loaded package TILMedia 1.9.0 ClaRa due to usage. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt master/SimCenter.mo:132:3-133:189:writable] Error: Class TILMedia.VLEFluidTypes.TILMedia_SplineWater not found in scope SimCenter. " [Timeout remaining time 659] [Calling sys.exit(0), Time elapsed: 20.52151310298359] Failed to read output from testmodel.py, exit status != 0: 1.027972134994343 1.044816501 -1.0 Calling exit ...