Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo): time 1.146/1.146, allocations: 153.8 MB / 173.5 MB, free: 4.844 MB / 142.1 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo) Running command: translateModel(ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50,tolerance=0.001,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50") translateModel(ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50,tolerance=0.001,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50") [Timeout 660] "Notification: Performance of FrontEnd - Absyn->SCode: time 1.969e-05/1.969e-05, allocations: 2.281 kB / 251.2 MB, free: 3.793 MB / 206.1 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50): time 2.269/2.269, allocations: 402 MB / 0.6378 GB, free: 1.852 MB / 494.1 MB Notification: Performance of NFInst.instExpressions: time 0.8702/3.139, allocations: 228.1 MB / 0.8606 GB, free: 1.906 MB / 0.6544 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.03621/3.175, allocations: 0.5959 MB / 0.8611 GB, free: 1.906 MB / 0.6544 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:134:3-135:75:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:136:3-137:75:writable] Warning: Connector Cm is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:138:3-139:77:writable] Warning: Connector Cd is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:140:3-141:65:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:155:3-157:58:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:158:3-159:76:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:160:3-161:66:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:134:3-135:75:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:136:3-137:75:writable] Warning: Connector Cm is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:138:3-139:77:writable] Warning: Connector Cd is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:140:3-141:65:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:155:3-157:58:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:158:3-159:76:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:160:3-161:66:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeB.mo:104:3-105:67:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeB.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeB.mo:109:3-111:57:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeB.mo:112:3-113:75:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:134:3-135:75:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:136:3-137:75:writable] Warning: Connector Cm is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:138:3-139:77:writable] Warning: Connector Cd is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:140:3-141:65:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:155:3-157:58:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:158:3-159:76:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:160:3-161:66:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SinkP.mo:47:3-48:67:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:65:3-66:54:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:67:3-68:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:72:3-76:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:65:3-66:54:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:67:3-68:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:72:3-76:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:65:3-66:54:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:67:3-68:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:72:3-76:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:43:3-44:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:45:3-46:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:43:3-44:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:45:3-46:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:43:3-44:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:45:3-46:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:119:3-120:52:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:121:3-122:53:writable] Warning: Connector Cl is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:129:3-130:55:writable] Warning: Connector Cee is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:131:3-132:53:writable] Warning: Connector Cse is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SourceQ.mo:63:3-64:65:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SinkP.mo:47:3-48:67:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeA.mo:104:3-105:67:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeA.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeA.mo:109:3-110:73:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeA.mo:111:3-112:75:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StaticCentrifugalPump.mo:63:3-64:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StaticCentrifugalPump.mo:65:3-66:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StaticCentrifugalPump.mo:63:3-64:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StaticCentrifugalPump.mo:65:3-66:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:43:3-44:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:45:3-46:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:43:3-44:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:45:3-46:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StaticCentrifugalPump.mo:63:3-64:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StaticCentrifugalPump.mo:65:3-66:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeD.mo:104:3-105:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeD.mo:106:3-107:73:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeD.mo:108:3-109:75:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeD.mo:110:3-111:71:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Combustion/BoundaryConditions/FuelSourcePQ.mo:26:3-28:26:writable] Warning: Connector C is not balanced: The number of potential variables (13) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SourcePQ.mo:75:3-76:65:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/AirHumidity.mo:40:3-41:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/AirHumidity.mo:48:3-49:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/Compressor.mo:50:3-51:54:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/Compressor.mo:52:3-53:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Combustion/CombustionChambers/GTCombustionChamber.mo:102:3-104:16:writable] Warning: Connector Cfuel is not balanced: The number of potential variables (13) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Combustion/CombustionChambers/GTCombustionChamber.mo:105:3-107:16:writable] Warning: Connector Ca is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Combustion/CombustionChambers/GTCombustionChamber.mo:108:3-109:83:writable] Warning: Connector Cfg is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Combustion/CombustionChambers/GTCombustionChamber.mo:110:3-112:17:writable] Warning: Connector Cws is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/CombustionTurbine.mo:40:3-41:54:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/CombustionTurbine.mo:42:3-43:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/GasTurbine.mo:57:3-58:65:writable] Warning: Connector Entree_air is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/GasTurbine.mo:59:3-60:63:writable] Warning: Connector Sortie_fumees is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/GasTurbine.mo:61:3-62:66:writable] Warning: Connector Entree_eau_combustion is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/GasTurbine.mo:63:3-64:82:writable] Warning: Connector Entree_combustible is not balanced: The number of potential variables (13) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.02779/3.203, allocations: 6.306 MB / 0.8673 GB, free: 1.863 MB / 0.6544 GB Notification: Performance of NFTyping.typeBindings: time 0.06998/3.273, allocations: 18.66 MB / 0.8855 GB, free: 15.1 MB / 0.67 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:783:9-783:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:850:9-850:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:1088:9-1088:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/Fluid/derDensity_derP_derh.mo:63:5-63:84:writable] Warning: T was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:1445:9-1445:35:writable] Warning: h was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ps.mo:71:3-71:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ps.mo:71:3-71:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.1221/3.395, allocations: 37.47 MB / 0.9221 GB, free: 7.539 MB / 0.6857 GB Notification: Performance of NFFlatten.flatten: time 0.1334/3.528, allocations: 76.6 MB / 0.9969 GB, free: 15.61 MB / 0.7482 GB Notification: Performance of NFFlatten.resolveConnections: time 0.06284/3.591, allocations: 24.93 MB / 1.021 GB, free: 6.945 MB / 0.7638 GB Notification: Performance of NFEvalConstants.evaluate: time 0.08564/3.677, allocations: 35.43 MB / 1.056 GB, free: 5.047 MB / 0.795 GB Notification: Performance of NFSimplifyModel.simplify: time 0.05686/3.734, allocations: 27.6 MB / 1.083 GB, free: 11.69 MB / 0.8263 GB Notification: Performance of NFPackage.collectConstants: time 0.02505/3.759, allocations: 5.121 MB / 1.088 GB, free: 6.566 MB / 0.8263 GB Notification: Performance of NFFlatten.collectFunctions: time 0.09301/3.852, allocations: 33.9 MB / 1.121 GB, free: 5.094 MB / 0.8575 GB Notification: Performance of combineBinaries: time 0.9493/4.801, allocations: 88.68 MB / 1.208 GB, free: 82.95 MB / 0.8577 GB Notification: Performance of replaceArrayConstructors: time 0.05705/4.858, allocations: 52.36 MB / 1.259 GB, free: 54.75 MB / 0.8577 GB Notification: Performance of NFVerifyModel.verify: time 0.02548/4.884, allocations: 3.202 MB / 1.262 GB, free: 54.75 MB / 0.8577 GB Notification: Performance of FrontEnd: time 0.01103/4.895, allocations: 1.04 MB / 1.263 GB, free: 54.55 MB / 0.8577 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 15489 (8270) * Number of variables: 15489 (9108) Notification: Performance of [SIM] Bindings: time 1.143/6.037, allocations: 262.8 MB / 1.519 GB, free: 87.88 MB / 0.9514 GB Notification: Performance of [SIM] FunctionAlias: time 0.09738/6.135, allocations: 42.5 MB / 1.561 GB, free: 82.88 MB / 0.9514 GB Notification: Performance of [SIM] Early Inline: time 0.3783/6.513, allocations: 229.7 MB / 1.785 GB, free: 8.273 MB / 1.014 GB Notification: Performance of [SIM] Simplify 1: time 0.09546/6.609, allocations: 27.41 MB / 1.812 GB, free: 2.656 MB / 1.03 GB Warning: NBAlias.setStartFixed: Alias set with conflicting unfixed start values detected. Use -d=dumprepl for more information. Notification: Performance of [SIM] Alias: time 1.004/7.612, allocations: 204.6 MB / 2.012 GB, free: 123.3 MB / 1.076 GB Notification: Performance of [SIM] Simplify 2: time 0.06045/7.673, allocations: 21.38 MB / 2.033 GB, free: 120 MB / 1.076 GB Notification: Performance of [SIM] Remove Stream: time 0.04327/7.716, allocations: 12.6 MB / 2.045 GB, free: 118.8 MB / 1.076 GB Notification: Performance of [SIM] Detect States: time 0.05993/7.776, allocations: 33.68 MB / 2.078 GB, free: 115.3 MB / 1.076 GB Notification: Performance of [SIM] Events: time 0.02732/7.803, allocations: 8.342 MB / 2.086 GB, free: 111.4 MB / 1.076 GB Notification: Performance of [SIM] Partitioning: time 0.1761/7.979, allocations: 62.85 MB / 2.147 GB, free: 60.36 MB / 1.076 GB Error: Internal error NBResolveSingularities.indexReduction failed because slicing during index reduction is not yet supported. needed sliced dummy: [STAT] (3) Real[3] EconomiseurBP.TwoPhaseFlowPipe.BQ slice: {0} " [Timeout remaining time 651] [Calling sys.exit(0), Time elapsed: 11.546433456998784] Failed to read output from testmodel.py, exit status != 0: 9.498605993983801 9.868099857 4.969765289 Calling exit ...