Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo): time 0.8824/0.8824, allocations: 153.8 MB / 173.5 MB, free: 4.848 MB / 142.1 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo) Running command: translateModel(ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC,tolerance=0.001,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC") translateModel(ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC,tolerance=0.001,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC") [Timeout 660] "Notification: Performance of FrontEnd - Absyn->SCode: time 2.045e-05/2.045e-05, allocations: 3.594 kB / 251.2 MB, free: 3.812 MB / 206.1 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC): time 2.177/2.177, allocations: 374.2 MB / 0.6107 GB, free: 10.75 MB / 478.1 MB Notification: Performance of NFInst.instExpressions: time 0.2982/2.475, allocations: 201.7 MB / 0.8077 GB, free: 3.828 MB / 0.6544 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.02306/2.498, allocations: 239.1 kB / 0.8079 GB, free: 3.594 MB / 0.6544 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:96:3-98:48:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:99:3-101:48:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:102:3-104:50:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:105:3-107:46:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:121:3-123:47:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:124:3-126:49:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:127:3-129:47:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:96:3-98:48:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:99:3-101:48:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:102:3-104:50:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:105:3-107:46:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:121:3-123:47:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:124:3-126:49:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:127:3-129:47:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeB.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeB.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeB.mo:35:3-37:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeB.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:96:3-98:48:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:99:3-101:48:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:102:3-104:50:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:105:3-107:46:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:121:3-123:47:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:124:3-126:49:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/DynamicDrum.mo:127:3-129:47:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/BoundaryConditions/SinkP.mo:16:3-18:16:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:16:3-18:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:19:3-20:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:16:3-18:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:19:3-20:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:16:3-18:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:19:3-20:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:89:3-90:45:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:91:3-92:46:writable] Warning: Connector Cl is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:99:3-100:48:writable] Warning: Connector Cee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:101:3-102:43:writable] Warning: Connector Cse is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/SourceQ.mo:24:3-25:52:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/SinkP.mo:33:3-34:47:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StaticCentrifugalPump.mo:60:3-62:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StaticCentrifugalPump.mo:63:3-65:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StaticCentrifugalPump.mo:60:3-62:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StaticCentrifugalPump.mo:63:3-65:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:16:3-18:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:19:3-20:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:16:3-18:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Junctions/MassFlowMultiplier.mo:19:3-20:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StaticCentrifugalPump.mo:60:3-62:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Machines/StaticCentrifugalPump.mo:63:3-65:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:29:3-31:42:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:32:3-34:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:35:3-37:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:38:3-40:37:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/BoundaryConditions/SourceQ.mo:17:3-18:83:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.4104/2.908, allocations: 4.59 MB / 0.8124 GB, free: 3.879 MB / 0.6544 GB Notification: Performance of NFTyping.typeBindings: time 0.04165/2.95, allocations: 13.82 MB / 0.8259 GB, free: 3.527 MB / 0.6544 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:783:9-783:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:850:9-850:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:1088:9-1088:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:1445:9-1445:35:writable] Warning: h was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ps.mo:71:3-71:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ps.mo:71:3-71:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.06937/3.019, allocations: 26.97 MB / 0.8523 GB, free: 3.051 MB / 0.6544 GB Notification: Performance of NFFlatten.flatten: time 0.08012/3.099, allocations: 53.92 MB / 0.9049 GB, free: 14.33 MB / 0.67 GB Notification: Performance of NFFlatten.resolveConnections: time 0.03623/3.136, allocations: 15.51 MB / 0.9201 GB, free: 5.824 MB / 0.67 GB Notification: Performance of NFEvalConstants.evaluate: time 0.0568/3.192, allocations: 24.63 MB / 0.9441 GB, free: 1.195 MB / 0.6857 GB Notification: Performance of NFSimplifyModel.simplify: time 0.04301/3.235, allocations: 20.51 MB / 0.9641 GB, free: 15.02 MB / 0.7169 GB Notification: Performance of NFPackage.collectConstants: time 0.01612/3.252, allocations: 3.375 MB / 0.9674 GB, free: 11.64 MB / 0.7169 GB Notification: Performance of NFFlatten.collectFunctions: time 0.07193/3.323, allocations: 26.74 MB / 0.9935 GB, free: 1.406 MB / 0.7325 GB Notification: Performance of combineBinaries: time 0.09848/3.422, allocations: 61.45 MB / 1.054 GB, free: 7.637 MB / 0.795 GB Notification: Performance of replaceArrayConstructors: time 0.04963/3.472, allocations: 36.38 MB / 1.089 GB, free: 5.066 MB / 0.8263 GB Notification: Performance of NFVerifyModel.verify: time 0.01456/3.486, allocations: 2.008 MB / 1.091 GB, free: 3.059 MB / 0.8263 GB Notification: Performance of FrontEnd: time 0.00482/3.491, allocations: 0.5715 MB / 1.092 GB, free: 2.562 MB / 0.8263 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 10686 (4497) * Number of variables: 10686 (5854) Notification: Performance of [SIM] Bindings: time 0.7181/4.209, allocations: 193.1 MB / 1.28 GB, free: 115 MB / 0.8575 GB Notification: Performance of [SIM] FunctionAlias: time 0.05503/4.264, allocations: 30.73 MB / 1.31 GB, free: 93.59 MB / 0.8575 GB Notification: Performance of [SIM] Early Inline: time 0.7867/5.051, allocations: 178.6 MB / 1.485 GB, free: 97.3 MB / 0.9044 GB Notification: Performance of [SIM] Simplify 1: time 0.07679/5.128, allocations: 21.33 MB / 1.505 GB, free: 94.19 MB / 0.9044 GB Warning: NBAlias.setStartFixed: Alias set with conflicting unfixed start values detected. Use -d=dumprepl for more information. Notification: Performance of [SIM] Alias: time 0.279/5.407, allocations: 127.4 MB / 1.63 GB, free: 64.11 MB / 0.9044 GB Notification: Performance of [SIM] Simplify 2: time 0.06084/5.467, allocations: 18.93 MB / 1.648 GB, free: 54.88 MB / 0.9044 GB Notification: Performance of [SIM] Remove Stream: time 0.034/5.501, allocations: 10.67 MB / 1.659 GB, free: 44.31 MB / 0.9044 GB Notification: Performance of [SIM] Detect States: time 0.05842/5.56, allocations: 28.67 MB / 1.687 GB, free: 16.43 MB / 0.9044 GB Notification: Performance of [SIM] Events: time 0.01849/5.578, allocations: 6.306 MB / 1.693 GB, free: 10.49 MB / 0.9044 GB Notification: Performance of [SIM] Partitioning: time 0.1622/5.741, allocations: 51.11 MB / 1.743 GB, free: 8.008 MB / 0.9513 GB Error: Internal error NBResolveSingularities.indexReduction failed because slicing during index reduction is not yet supported. needed sliced dummy: [STAT] (5) Real[5] EconomiseurBP.TwoPhaseFlowPipe.Pb (start = {1e5 for $f2 in 1:5}, min = {0.0 for $f3 in 1:5}, nominal = {1e5 for $f1 in 1:5}) slice: {0, 1, 2, 3} " [Timeout remaining time 653] [Calling sys.exit(0), Time elapsed: 8.843834541970864] Failed to read output from testmodel.py, exit status != 0: 7.42164962698007 7.434456934 3.93965787 Calling exit ...