Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo): time 0.9107/0.9107, allocations: 153.8 MB / 173.5 MB, free: 4.285 MB / 142.1 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo) Running command: translateModel(ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow") translateModel(ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow") [Timeout 660] "Notification: Performance of FrontEnd - Absyn->SCode: time 2.573e-05/2.573e-05, allocations: 4.812 kB / 251.1 MB, free: 3.816 MB / 206.1 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow): time 2.208/2.209, allocations: 317.5 MB / 0.5553 GB, free: 6.168 MB / 430.1 MB Notification: Performance of NFInst.instExpressions: time 0.2346/2.443, allocations: 169.8 MB / 0.7212 GB, free: 13.96 MB / 0.5919 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.00477/2.448, allocations: 39.88 kB / 0.7212 GB, free: 13.93 MB / 0.5919 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/SourceP.mo:30:3-31:45:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/SinkP.mo:33:3-34:47:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/TwoPhaseCavity.mo:178:3-180:46:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/TwoPhaseCavity.mo:181:3-183:56:writable] Warning: Connector Cl is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/TwoPhaseCavity.mo:194:3-196:48:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:115:3-116:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:117:3-118:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:80:3-81:83:writable] Warning: Connector C1vap is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:82:3-84:16:writable] Warning: Connector C2ex is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:85:3-87:24:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:88:3-90:17:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicWaterHeating.mo:95:3-97:17:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:115:3-116:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:117:3-118:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:115:3-116:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:117:3-118:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:29:3-31:42:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:32:3-34:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:35:3-37:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:38:3-40:37:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:29:3-31:42:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:32:3-34:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:35:3-37:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/Volumes/VolumeD.mo:38:3-40:37:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/Sink.mo:17:3-19:16:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/SourceP.mo:30:3-31:45:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/RefQ.mo:15:3-17:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/BoundaryConditions/RefQ.mo:18:3-19:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/IdealCheckValve.mo:22:3-23:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/IdealCheckValve.mo:24:3-25:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/LumpedStraightPipe.mo:49:3-50:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/WaterSteam/PressureLosses/LumpedStraightPipe.mo:51:3-53:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.003403/2.451, allocations: 0.8555 MB / 0.722 GB, free: 13.07 MB / 0.5919 GB Notification: Performance of NFTyping.typeBindings: time 0.006893/2.458, allocations: 2.009 MB / 0.724 GB, free: 11.05 MB / 0.5919 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:783:9-783:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:850:9-850:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:1088:9-1088:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.04004/2.498, allocations: 13.57 MB / 0.7372 GB, free: 13.46 MB / 0.6075 GB Notification: Performance of NFFlatten.flatten: time 0.01185/2.51, allocations: 7.717 MB / 0.7448 GB, free: 5.727 MB / 0.6075 GB Notification: Performance of NFFlatten.resolveConnections: time 0.003747/2.514, allocations: 2.108 MB / 0.7468 GB, free: 3.578 MB / 0.6075 GB Notification: Performance of NFEvalConstants.evaluate: time 0.006238/2.52, allocations: 3.3 MB / 0.7501 GB, free: 276 kB / 0.6075 GB Notification: Performance of NFSimplifyModel.simplify: time 0.004712/2.525, allocations: 2.638 MB / 0.7526 GB, free: 13.62 MB / 0.6232 GB Notification: Performance of NFPackage.collectConstants: time 0.001154/2.526, allocations: 424 kB / 0.753 GB, free: 13.21 MB / 0.6232 GB Notification: Performance of NFFlatten.collectFunctions: time 0.4597/2.986, allocations: 19.5 MB / 0.7721 GB, free: 26.19 MB / 0.6232 GB Notification: Performance of combineBinaries: time 0.01545/3.001, allocations: 8.519 MB / 0.7804 GB, free: 24.11 MB / 0.6232 GB Notification: Performance of replaceArrayConstructors: time 0.006321/3.007, allocations: 5.381 MB / 0.7857 GB, free: 21.29 MB / 0.6232 GB Notification: Performance of NFVerifyModel.verify: time 0.001894/3.009, allocations: 314.9 kB / 0.786 GB, free: 21.29 MB / 0.6232 GB Notification: Performance of FrontEnd: time 0.000837/3.01, allocations: 90.69 kB / 0.786 GB, free: 21.27 MB / 0.6232 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 3749 (626) * Number of variables: 3751 (884) Notification: Performance of [SIM] Bindings: time 0.03291/3.043, allocations: 26.16 MB / 0.8116 GB, free: 12.24 MB / 0.6232 GB Notification: Performance of [SIM] FunctionAlias: time 0.007638/3.051, allocations: 4.065 MB / 0.8156 GB, free: 11.45 MB / 0.6232 GB Notification: Performance of [SIM] Early Inline: time 0.03988/3.091, allocations: 24.29 MB / 0.8393 GB, free: 8.309 MB / 0.6232 GB Notification: Performance of [SIM] Simplify 1: time 0.01106/3.102, allocations: 2.87 MB / 0.8421 GB, free: 7.285 MB / 0.6232 GB Warning: NBAlias.setStartFixed: Alias set with conflicting unfixed start values detected. Use -d=dumprepl for more information. Notification: Performance of [SIM] Alias: time 0.04064/3.142, allocations: 20.5 MB / 0.8621 GB, free: 13.59 MB / 0.6388 GB Notification: Performance of [SIM] Simplify 2: time 0.005374/3.148, allocations: 2.439 MB / 0.8645 GB, free: 12.73 MB / 0.6388 GB Notification: Performance of [SIM] Remove Stream: time 0.002721/3.15, allocations: 1.443 MB / 0.8659 GB, free: 11.86 MB / 0.6388 GB Notification: Performance of [SIM] Detect States: time 0.006099/3.156, allocations: 4.002 MB / 0.8698 GB, free: 9.438 MB / 0.6388 GB Notification: Performance of [SIM] Events: time 0.002046/3.158, allocations: 0.8565 MB / 0.8706 GB, free: 8.988 MB / 0.6388 GB Error: Internal error NBPartitioning.partitioningClocked (ODE) failed because the following variables could not be assigned to a partition: {[ALGB] (1) Real regulation_Niveau.MesureDebitEau.signal [ALGB] (1) Real regulation_Niveau.MesureDebitVapeur.signal} " [Timeout remaining time 657] [Calling sys.exit(0), Time elapsed: 4.837433170992881] Failed to read output from testmodel.py, exit status != 0: 3.3711593369953334 3.384649868 0.37095778500000004 Calling exit ...