Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_dev_Dynawo.Examples.IllustrativeExamples.DynaFlow.CoordinatedVControl.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001168/0.001168, allocations: 104.3 kB / 20.53 MB, free: 1.285 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001226/0.001226, allocations: 225 kB / 23.84 MB, free: 4.426 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.18/1.18, allocations: 207.7 MB / 234.7 MB, free: 9.742 MB / 190.1 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/package.mo): time 0.5519/0.5519, allocations: 115 MB / 402 MB, free: 16.52 MB / 318.1 MB " [Timeout remaining time 179] Using package Dynawo with version 1.8.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(Dynawo.Examples.IllustrativeExamples.DynaFlow.CoordinatedVControl,tolerance=1e-06,outputFormat="mat",numberOfIntervals=300,variableFilter="time|Generator1.PGenPu|Generator1.QGenPu|Generator1.UPu|Generator2.PGenPu|Generator2.QGenPu|Generator2.UPu",fileNamePrefix="Dynawo_dev_Dynawo.Examples.IllustrativeExamples.DynaFlow.CoordinatedVControl") translateModel(Dynawo.Examples.IllustrativeExamples.DynaFlow.CoordinatedVControl,tolerance=1e-06,outputFormat="mat",numberOfIntervals=300,variableFilter="time|Generator1.PGenPu|Generator1.QGenPu|Generator1.UPu|Generator2.PGenPu|Generator2.QGenPu|Generator2.UPu",fileNamePrefix="Dynawo_dev_Dynawo.Examples.IllustrativeExamples.DynaFlow.CoordinatedVControl") [Timeout 660] "Notification: Performance of FrontEnd - Absyn->SCode: time 1.418e-05/1.418e-05, allocations: 2.281 kB / 0.5656 GB, free: 44.39 MB / 462.1 MB Notification: Performance of NFInst.instantiate(Dynawo.Examples.IllustrativeExamples.DynaFlow.CoordinatedVControl): time 0.004244/0.004258, allocations: 4.036 MB / 0.5695 GB, free: 41.75 MB / 462.1 MB Notification: Performance of NFInst.instExpressions: time 0.005663/0.009921, allocations: 5.028 MB / 0.5744 GB, free: 38.25 MB / 462.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.0005553/0.01048, allocations: 15.59 kB / 0.5744 GB, free: 38.24 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:30:3-30:140:writable] Warning: Connector QGenPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:32:3-32:113:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:30:3-30:140:writable] Warning: Connector QGenPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:32:3-32:113:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Events/Event/EventEquations.mo:23:3-23:39:writable] Warning: Connector state1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/SignalN/BaseClasses_INIT/BaseGeneratorSignalN_INIT.mo:25:3-25:135:writable] Warning: Connector PGen0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/SignalN/BaseClasses_INIT/BaseGeneratorSignalN_INIT.mo:27:3-27:151:writable] Warning: Connector QGen0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/SignalN/BaseClasses_INIT/BaseGeneratorSignalN_INIT.mo:28:3-28:118:writable] Warning: Connector U0PuVar is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/SignalN/BaseClasses_INIT/BaseGeneratorSignalN_INIT.mo:30:3-30:114:writable] Warning: Connector u0Pu is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/SignalN/BaseClasses_INIT/BaseGeneratorSignalN_INIT.mo:32:3-32:169:writable] Warning: Connector i0Pu is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/SignalN/BaseClasses_INIT/BaseGeneratorSignalNPQDiagram_INIT.mo:25:3-25:135:writable] Warning: Connector PGen0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/SignalN/BaseClasses_INIT/BaseGeneratorSignalNPQDiagram_INIT.mo:27:3-27:151:writable] Warning: Connector QGen0Pu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/SignalN/BaseClasses_INIT/BaseGeneratorSignalNPQDiagram_INIT.mo:28:3-28:118:writable] Warning: Connector U0PuVar is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/SignalN/BaseClasses_INIT/BaseGeneratorSignalNPQDiagram_INIT.mo:30:3-30:114:writable] Warning: Connector u0Pu is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/SignalN/BaseClasses_INIT/BaseGeneratorSignalNPQDiagram_INIT.mo:32:3-32:169:writable] Warning: Connector i0Pu is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.0008391/0.01132, allocations: 282.5 kB / 0.5747 GB, free: 38.11 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Utilities/Strings.mo:139:3-175:14:writable] Warning: Pure function 'Modelica.Utilities.Strings.isEmpty' contains a call to impure function 'Modelica.Utilities.Strings.Advanced.skipWhiteSpace'. Notification: Performance of NFTyping.typeBindings: time 0.0009632/0.01228, allocations: 292.3 kB / 0.575 GB, free: 37.93 MB / 462.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:40:5-44:11:writable] Warning: In relation Generator1.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:40:5-44:11:writable] Warning: In relation Generator1.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:40:5-44:11:writable] Warning: In relation Generator2.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:40:5-44:11:writable] Warning: In relation Generator2.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. Notification: Performance of NFTyping.typeClassSections: time 0.002276/0.01455, allocations: 1.183 MB / 0.5761 GB, free: 37.29 MB / 462.1 MB Notification: Performance of NFFlatten.flatten: time 0.001498/0.01605, allocations: 1.406 MB / 0.5775 GB, free: 36.61 MB / 462.1 MB Notification: Performance of NFFlatten.resolveConnections: time 0.000324/0.01638, allocations: 98.89 kB / 0.5776 GB, free: 36.56 MB / 462.1 MB Notification: Performance of NFEvalConstants.evaluate: time 0.0007016/0.01708, allocations: 0.5787 MB / 0.5782 GB, free: 36.28 MB / 462.1 MB Notification: Performance of NFSimplifyModel.simplify: time 0.0006642/0.01774, allocations: 473.3 kB / 0.5786 GB, free: 36.07 MB / 462.1 MB Notification: Performance of NFPackage.collectConstants: time 0.0002093/0.01795, allocations: 89.78 kB / 0.5787 GB, free: 36.07 MB / 462.1 MB Notification: Performance of NFFlatten.collectFunctions: time 0.0006183/0.01857, allocations: 309.8 kB / 0.579 GB, free: 36 MB / 462.1 MB Notification: Performance of combineBinaries: time 0.001142/0.01971, allocations: 1.941 MB / 0.5809 GB, free: 34.66 MB / 462.1 MB Notification: Performance of replaceArrayConstructors: time 0.0005549/0.02027, allocations: 1.2 MB / 0.5821 GB, free: 33.81 MB / 462.1 MB Notification: Performance of NFVerifyModel.verify: time 0.0002147/0.02048, allocations: 56.25 kB / 0.5821 GB, free: 33.81 MB / 462.1 MB Notification: Performance of FrontEnd: time 6.142e-05/0.02054, allocations: 20.66 kB / 0.5821 GB, free: 33.8 MB / 462.1 MB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 153 (137) * Number of variables: 153 (151) Notification: Performance of [SIM] Bindings: time 0.003048/0.02359, allocations: 4.866 MB / 0.5869 GB, free: 30.52 MB / 462.1 MB Notification: Performance of [SIM] FunctionAlias: time 0.0003564/0.02395, allocations: 481.4 kB / 0.5874 GB, free: 30.23 MB / 462.1 MB Notification: Performance of [SIM] Early Inline: time 0.003697/0.02764, allocations: 5.084 MB / 0.5923 GB, free: 27.5 MB / 462.1 MB Notification: Performance of [SIM] Simplify 1: time 0.0007198/0.02836, allocations: 0.6196 MB / 0.5929 GB, free: 27.23 MB / 462.1 MB Warning: NBAlias.setStartFixed: Alias set with conflicting unfixed start values detected. Use -d=dumprepl for more information. Notification: Performance of [SIM] Alias: time 0.002756/0.03112, allocations: 3.137 MB / 0.596 GB, free: 25.02 MB / 462.1 MB Notification: Performance of [SIM] Simplify 2: time 0.0005548/0.03168, allocations: 0.5334 MB / 0.5965 GB, free: 24.7 MB / 462.1 MB Notification: Performance of [SIM] Remove Stream: time 0.0002173/0.03189, allocations: 338.7 kB / 0.5968 GB, free: 24.4 MB / 462.1 MB Notification: Performance of [SIM] Detect States: time 0.0006211/0.03251, allocations: 0.9507 MB / 0.5978 GB, free: 23.56 MB / 462.1 MB Notification: Performance of [SIM] Events: time 0.0005326/0.03305, allocations: 0.5429 MB / 0.5983 GB, free: 23.16 MB / 462.1 MB Notification: Performance of [SIM] Partitioning: time 0.001128/0.03417, allocations: 1.431 MB / 0.5997 GB, free: 22.2 MB / 462.1 MB Error: NBCausalize.checkSystemVariabilities failed. The following strong component has conflicting types: Real != Integer BLOCK: Single Strong Component (status = Solve.UNPROCESSED, size = 1) ----------------------------------------------------------------------- ### Variable: Real Generator2.genState ### Equation: [SCAL] (1) Generator2.genState = Integer(Generator2.state) ($RES_SIM_104) Error: NBCausalize.checkSystemVariabilities failed. The following strong component has conflicting types: Real != Integer BLOCK: Single Strong Component (status = Solve.UNPROCESSED, size = 1) ----------------------------------------------------------------------- ### Variable: Real Generator1.genState ### Equation: [SCAL] (1) Generator1.genState = Integer(Generator1.state) ($RES_SIM_140) " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 2.7104008739697747] Failed to read output from testmodel.py, exit status != 0: 0.043032977962866426 0.05154546 0.029200488 Calling exit ...