Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr BuildingSystems_BuildingSystems.Technologies.SolarThermal.Examples.SingleCollectorWithStorageTest.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001589/0.001589, allocations: 104.3 kB / 19.76 MB, free: 1.906 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001679/0.001679, allocations: 214 kB / 23.06 MB, free: 4.984 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.33/1.33, allocations: 230.7 MB / 256.9 MB, free: 7.711 MB / 206.1 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 master/package.mo): time 0.002317/0.002317, allocations: 285.2 kB / 313.6 MB, free: 2.555 MB / 238.1 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/package.mo): time 1.127/1.127, allocations: 180.7 MB / 0.5378 GB, free: 14.44 MB / 382.1 MB " [Timeout remaining time 179] Using package BuildingSystems with version 2.0.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/package.mo) Using package NcDataReader2 with version 2.5.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(BuildingSystems.Technologies.SolarThermal.Examples.SingleCollectorWithStorageTest,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Technologies.SolarThermal.Examples.SingleCollectorWithStorageTest") translateModel(BuildingSystems.Technologies.SolarThermal.Examples.SingleCollectorWithStorageTest,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Technologies.SolarThermal.Examples.SingleCollectorWithStorageTest") [Timeout 660] "Notification: Performance of FrontEnd - Absyn->SCode: time 1.682e-05/1.682e-05, allocations: 4.672 kB / 0.7408 GB, free: 27.81 MB / 0.5294 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Technologies/SolarThermal/Examples/SingleCollectorWithStorageTest.mo:35:5-35:25:writable] Error: Modified element reverseAction not found in class LimPID. " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 3.681104185001459] Failed to read output from testmodel.py, exit status != 0: 0.052384415990673006 0.066425644 -1.0 Calling exit ...