OMSimulator -r ModelicaTest_3.2.2_fmi_cpp_ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpDCMotorHeatTransfer_res.mat --tempDir temp_ModelicaTest_3_2_2_fmi_cpp_ModelicaTest_Fluid_TestComponents_Machines_TestWaterPumpDCMotorHeatTransfer_fmu --startTime 0 --stopTime 8 --tolerance 1e-06 ModelicaTest_3_2_2_fmi_cpp_ModelicaTest_Fluid_TestComponents_Machines_TestWaterPumpDCMotorHeatTransfer.fmu info: Initializing logging (OMSimulator v0.0.0-204-g82c54af) info: new temp directory has been created: "temp_ModelicaTest_3_2_2_fmi_cpp_ModelicaTest_Fluid_TestComponents_Machines_TestWaterPumpDCMotorHeatTransfer_fmu" info: Using "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_fmi_cpp_ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpDCMotorHeatTransfer/temp_ModelicaTest_3_2_2_fmi_cpp_ModelicaTest_Fluid_TestComponents_Machines_TestWaterPumpDCMotorHeatTransfer_fmu/temp_YaJENL" as temp directory for fmu warning: ME-FMU instance (logStatusWarning): Variable violating min constraint: 0.0 <= pump.delta_head_init, has value: -50.149869 info: Result file: ModelicaTest_3.2.2_fmi_cpp_ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpDCMotorHeatTransfer_res.mat error: ME-FMU instance (logStatusError): Nonlinear solver 380 stopped at time 0.01 with error in algloop solver: Can't get sufficient decrease of solution fatal: fmi2_import_get_derivatives failed info: 1 warnings info: 2 errors info: Logging completed properly info: Initializing logging (OMSimulator v0.0.0-204-g82c54af) fatal: Time measurement is corrupted.