Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_master_Buildings.ThermalZones.Detailed.Examples.FFD.NaturalConvectionWithControl.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 9.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Examples.FFD.NaturalConvectionWithControl,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_master_Buildings.ThermalZones.Detailed.Examples.FFD.NaturalConvectionWithControl") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo): time 4.644/4.644, allocations: 0.5623 GB / 0.5769 GB, free: 3.32 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.00243/0.002429, allocations: 358.9 kB / 0.644 GB, free: 185.7 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 4.148/4.148, allocations: 410.7 MB / 1.112 GB, free: 5.953 MB / 0.6042 GB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001782/0.001782, allocations: 176 kB / 1.225 GB, free: 6.113 MB / 0.7136 GB Notification: Performance of FrontEnd - loaded program: time 0.0004878/0.0004881, allocations: 11.98 kB / 1.348 GB, free: 8.246 MB / 0.8386 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5851/0.5856, allocations: 115.3 MB / 1.461 GB, free: 284.4 MB / 0.8542 GB Notification: Performance of NFInst.instantiate(Buildings.ThermalZones.Detailed.Examples.FFD.NaturalConvectionWithControl): time 0.1784/0.764, allocations: 182.1 MB / 1.639 GB, free: 102.2 MB / 0.8542 GB Notification: Performance of NFInst.instExpressions: time 0.04421/0.8083, allocations: 25.8 MB / 1.664 GB, free: 76.36 MB / 0.8542 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01117/0.8195, allocations: 222.6 kB / 1.664 GB, free: 76.14 MB / 0.8542 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFExpression.mo:1425:7-1426:100:writable] Error: Internal error NFExpression.makeSubscriptedExp: too few dimensions in 1 to apply subscripts [] [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): roo.conExt.layers.nLay which gives dimensions of array: material. Array dimensions must be known at compile time. Notification: Performance of FrontEnd: time 0.004296/0.8239, allocations: 1.263 MB / 1.665 GB, free: 74.88 MB / 0.8542 GB