Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_master_Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 9.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_master_Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo): time 4.736/4.736, allocations: 0.5623 GB / 0.577 GB, free: 3.359 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.002396/0.002395, allocations: 361.1 kB / 0.644 GB, free: 185.6 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 4.158/4.158, allocations: 410.8 MB / 1.112 GB, free: 6.102 MB / 0.6042 GB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001836/0.001836, allocations: 181.6 kB / 1.225 GB, free: 6.156 MB / 0.7136 GB Notification: Performance of FrontEnd - loaded program: time 0.0004887/0.0004891, allocations: 16 kB / 1.348 GB, free: 8.289 MB / 0.8386 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5825/0.583, allocations: 115.3 MB / 1.461 GB, free: 284.3 MB / 0.8542 GB Notification: Performance of NFInst.instantiate(Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection): time 0.1854/0.7685, allocations: 188.9 MB / 1.645 GB, free: 95.27 MB / 0.8542 GB Notification: Performance of NFInst.instExpressions: time 0.04448/0.813, allocations: 26.07 MB / 1.671 GB, free: 69.18 MB / 0.8542 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01139/0.8245, allocations: 214.6 kB / 1.671 GB, free: 68.97 MB / 0.8542 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFExpression.mo:1425:7-1426:100:writable] Error: Internal error NFExpression.makeSubscriptedExp: too few dimensions in 1 to apply subscripts [] [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): roo.conExt.layers.nLay which gives dimensions of array: material. Array dimensions must be known at compile time. Notification: Performance of FrontEnd: time 0.003914/0.8284, allocations: 1.189 MB / 1.672 GB, free: 67.78 MB / 0.8542 GB