Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.ThermalZones.Detailed.Examples.FFD.Tutorial.NaturalConvection.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Examples.FFD.Tutorial.NaturalConvection,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.ThermalZones.Detailed.Examples.FFD.Tutorial.NaturalConvection") Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.01063/0.01063, allocations: 221.6 kB / 15.17 MB, free: 5.996 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.001103/0.001103, allocations: 176.3 kB / 16.06 MB, free: 5.871 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 3.909/3.909, allocations: 389.1 MB / 405.9 MB, free: 13.24 MB / 346.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 3.988/3.988, allocations: 472.3 MB / 0.9018 GB, free: 3.594 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.000494/0.0004946, allocations: 16 kB / 1.008 GB, free: 10.23 MB / 0.6667 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5643/0.5648, allocations: 98.7 MB / 1.104 GB, free: 212.8 MB / 0.7292 GB Notification: Performance of NFInst.instantiate(Buildings.ThermalZones.Detailed.Examples.FFD.Tutorial.NaturalConvection): time 0.1968/0.7617, allocations: 181.2 MB / 1.281 GB, free: 57.01 MB / 0.7292 GB Notification: Performance of NFInst.instExpressions: time 0.04346/0.8052, allocations: 25.52 MB / 1.306 GB, free: 31.5 MB / 0.7292 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01129/0.8165, allocations: 206.6 kB / 1.306 GB, free: 31.3 MB / 0.7292 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFExpression.mo:1425:7-1426:100:writable] Error: Internal error NFExpression.makeSubscriptedExp: too few dimensions in 1 to apply subscripts [] [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): roo.conExt.layers.nLay which gives dimensions of array: material. Array dimensions must be known at compile time. Notification: Performance of FrontEnd: time 0.00425/0.8208, allocations: 1.255 MB / 1.307 GB, free: 30.04 MB / 0.7292 GB