Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950FF,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_5.0.1_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950FF") Notification: Performance of loadModel(Buildings): time 3.515/3.515, allocations: 402 MB / 415.9 MB, free: 10.18 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 3.008e-05/3.034e-05, allocations: 4 kB / 0.5004 GB, free: 8.215 MB / 410.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.169/0.1691, allocations: 92.67 MB / 0.5909 GB, free: 11.36 MB / 0.4948 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.432/6.601, allocations: 2.332 GB / 2.923 GB, free: 198 MB / 0.7761 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004378/6.601, allocations: 118.3 kB / 2.923 GB, free: 198 MB / 0.7761 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2346:7-2347:66:writable] Warning: Unused input variable tableAvailable in function .Buildings.ThermalZones.Detailed.Validation.BESTEST.BaseClasses.DaySchedule$vent.getDerTableValue. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2312:7-2313:66:writable] Warning: Unused input variable tableAvailable in function .Buildings.ThermalZones.Detailed.Validation.BESTEST.BaseClasses.DaySchedule$vent.getTableValue. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2358:7-2359:66:writable] Warning: Unused input variable tableAvailable in function .Buildings.ThermalZones.Detailed.Validation.BESTEST.BaseClasses.DaySchedule$vent.getTableTimeTmin. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2369:7-2370:66:writable] Warning: Unused input variable tableAvailable in function .Buildings.ThermalZones.Detailed.Validation.BESTEST.BaseClasses.DaySchedule$vent.getTableTimeTmax. Error: Dimensions must be parameter or constant expression (in size(glass, 1)). [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 5.0.1/HeatTransfer/Data/GlazingSystems.mo:38:5-42:31:writable] Error: Dimensions must be parameter or constant expression (in size(glass, 1)). [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 5.0.1/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case600FF.mo:96:7-96:25:writable] Error: Component roo.datConExtWin[1].glaSys of variability PARAM has binding window600 of higher variability VAR. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950FF Notification: Performance of FrontEnd: time 1.713/8.315, allocations: 360 MB / 3.274 GB, free: 141.1 MB / 0.7761 GB