Running command: translateModel(Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_5.0.1_Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow") Notification: Performance of loadModel(Buildings): time 3.551/3.551, allocations: 402 MB / 415.9 MB, free: 10.12 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 3.061e-05/3.081e-05, allocations: 4 kB / 0.5003 GB, free: 8.238 MB / 410.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1707/0.1708, allocations: 92.68 MB / 0.5908 GB, free: 11.38 MB / 0.4948 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.415/1.586, allocations: 397.5 MB / 0.979 GB, free: 170.9 MB / 0.7448 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002606/1.586, allocations: 100.4 kB / 0.9791 GB, free: 170.8 MB / 0.7448 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 5.0.1/Fluid/Chillers/Validation/Carnot_TEva_reverseFlow.mo:22:3-37:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow Notification: Performance of FrontEnd: time 0.2125/1.798, allocations: 81.69 MB / 1.059 GB, free: 98.24 MB / 0.7448 GB