Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=4000 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.6 Regular simulation: ./TransiEnt_TransiEnt.Consumer.Systems.PVBatteryPoolControl.Base.Check.CheckPoolStoragePBPPotential -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00185658s reading init.xml | | | | | | 0.000164759s reading info.xml | | | | | | 7.7735e-05s [ 2.6%] pre-initialization | | | | | | 7.7215e-05s [ 2.6%] initialization | | | | | | 3.61e-07s [ 0.0%] steps | | | | | | 4.281e-06s [ 0.1%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | -5.73071e-21s [ -0.0%] event-handling | | | | | | 0.000282642s [ 9.4%] overhead | | | | | | 0.00253861s [ 84.9%] simulation | | | | | | 0.00299136s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 14 time events | | | | | solver: euler | | | | | | 43644 steps taken | | | | | | 43644 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.