Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=1200 tolerance=1e-05 numberOfIntervals=2500 stepSize=0.48 Regular simulation: ./TransiEnt_TransiEnt.Components.Heat.Fan.Check.TestFan -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Heat/Fan/Fan_L1.mo:188:2-188:62:writable] | | | | The following assertion has been violated at time 68.640000 | | | | ((fan.E_check >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan.E_check, has value: -1.29957e-13" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0435766s reading init.xml | | | | | | 0.00352725s reading info.xml | | | | | | 0.000223399s [ 0.2%] pre-initialization | | | | | | 0.0683391s [ 51.1%] initialization | | | | | | 8.095e-06s [ 0.0%] steps | | | | | | 0.00253152s [ 1.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00109852s [ 0.8%] event-handling | | | | | | 0.0110397s [ 8.3%] overhead | | | | | | 0.050374s [ 37.7%] simulation | | | | | | 0.133614s [100.0%] total | | | | | events | | | | | | 3 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 167 steps taken | | | | | | 205 calls of functionODE | | | | | | 54 evaluations of jacobian | | | | | | 5 error test failures | | | | | | 0 convergence test failures | | | | | | 3.9127e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.