Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 Regular simulation: ./TransiEnt_TransiEnt.Components.Electrical.FuelCellSystems.Check.TestFuelCellSystem_SOFC -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/BaseClasses/PartialGas_pT.mo:27:3-28:20:writable] | | | | The following assertion has been violated at time 2.160000 | | | | ((FC.synga.xi_dryGas[4] >= 0.0 and FC.synga.xi_dryGas[4] <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= FC.synga.xi_dryGas[4] <= 1.0, has value: -1.54557e-21" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/BaseClasses/PartialGas_pT.mo:29:3-29:50:writable] | | | | The following assertion has been violated at time 2.160000 | | | | ((FC.synga.x[5] >= 0.0 and FC.synga.x[5] <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= FC.synga.x[5] <= 1.0, has value: -1.127e-20" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/BaseClasses/PartialGas_pT.mo:44:3-44:56:writable] | | | | The following assertion has been violated at time 2.160000 | | | | ((FC.synga.p_i[5] >= 0.0)) --> "Variable violating min constraint: 0.0 <= FC.synga.p_i[5], has value: -1.127e-15" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/BaseClasses/PartialGas_pT.mo:25:3-26:39:writable] | | | | The following assertion has been violated at time 2.160000 | | | | ((FuelCellSensor.Syngas_InputCondition.xi[5] >= 0.0 and FuelCellSensor.Syngas_InputCondition.xi[5] <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= FuelCellSensor.Syngas_InputCondition.xi[5] <= 1.0, has value: -1.05872e-21" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/BaseClasses/PartialGas_pT.mo:27:3-28:20:writable] | | | | The following assertion has been violated at time 2.160000 | | | | ((FuelCellSensor.Syngas_InputCondition.xi_dryGas[4] >= 0.0 and FuelCellSensor.Syngas_InputCondition.xi_dryGas[4] <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= FuelCellSensor.Syngas_InputCondition.xi_dryGas[4] <= 1.0, has value: -1.54557e-21" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/BaseClasses/PartialGas_pT.mo:29:3-29:50:writable] | | | | The following assertion has been violated at time 2.160000 | | | | ((FuelCellSensor.Syngas_InputCondition.x[5] >= 0.0 and FuelCellSensor.Syngas_InputCondition.x[5] <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= FuelCellSensor.Syngas_InputCondition.x[5] <= 1.0, has value: -1.127e-20" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/BaseClasses/PartialGas_pT.mo:44:3-44:56:writable] | | | | The following assertion has been violated at time 2.160000 | | | | ((FuelCellSensor.Syngas_InputCondition.p_i[5] >= 0.0)) --> "Variable violating min constraint: 0.0 <= FuelCellSensor.Syngas_InputCondition.p_i[5], has value: -1.127e-15" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/BaseClasses/PartialGas_pT.mo:27:3-28:20:writable] | | | | The following assertion has been violated at time 2.160000 | | | | ((FuelCellSensor.Syngas_AmbientCondition.xi_dryGas[4] >= 0.0 and FuelCellSensor.Syngas_AmbientCondition.xi_dryGas[4] <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= FuelCellSensor.Syngas_AmbientCondition.xi_dryGas[4] <= 1.0, has value: -1.54557e-21" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/BaseClasses/PartialGas_pT.mo:29:3-29:50:writable] | | | | The following assertion has been violated at time 2.160000 | | | | ((FuelCellSensor.Syngas_AmbientCondition.x[5] >= 0.0 and FuelCellSensor.Syngas_AmbientCondition.x[5] <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= FuelCellSensor.Syngas_AmbientCondition.x[5] <= 1.0, has value: -1.127e-20" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/BaseClasses/PartialGas_pT.mo:44:3-44:56:writable] | | | | The following assertion has been violated at time 2.160000 | | | | ((FuelCellSensor.Syngas_AmbientCondition.p_i[5] >= 0.0)) --> "Variable violating min constraint: 0.0 <= FuelCellSensor.Syngas_AmbientCondition.p_i[5], has value: -1.7845e-15" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0371636s reading init.xml | | | | | | 0.00313021s reading info.xml | | | | | | 0.000216025s [ 0.1%] pre-initialization | | | | | | 0.0393546s [ 13.6%] initialization | | | | | | 4.0686e-05s [ 0.0%] steps | | | | | | 0.0041415s [ 1.4%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0470102s [ 16.2%] event-handling | | | | | | 0.00970467s [ 3.3%] overhead | | | | | | 0.189943s [ 65.4%] simulation | | | | | | 0.290411s [100.0%] total | | | | | events | | | | | | 3 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 257 steps taken | | | | | | 355 calls of functionODE | | | | | | 81 evaluations of jacobian | | | | | | 11 error test failures | | | | | | 2 convergence test failures | | | | | | 0.00278694s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.